OSHA Inspection: DAL-TILE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DAL-TILE CORPORATION in 359 CLAY RD., SUNNYVALE, TX 75182 (NAICS 327120). OSHA activity number 344997218.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dal-Tile Corporation — free Get an email when a new federal OSHA severe-injury report for Dal-Tile Corporation is published. One employer, no account, unsubscribe in one click.
Site address
359 CLAY RD.
City
SUNNYVALE
State
TX
ZIP
75182
Mailing
359 CLAY RD, SUNNYVALE, TX 75182
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327120
Employees
300
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 4 instances 20 exposed
Issued
Mar 12, 2021
Abate by
Apr 7, 2021
Penalty
Initial $13,653 · Current $8,192 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about October 26, 2020, and times prior thereto, the employer did not clearly and specifically outline rules and techniques for the control of all hazardous energy such as mechanical (i.e. gravity) energy at:      (a) In Plant 1, in the Sacmi Press dryer 3 exit elevator and dryer table, counterweight chain; (b) In Plant 1, in the Sacmi Press dryer 4 exit elevator and dryer table,  counterweight chain; (c) In Plant 1, in the  Sacmi Press dryer 5 exit elevator and dryer table counterweight chain; (d) In Plant 1, in the Sacmi Press dryer 6 exit elevator and dryer table counterweight chain.
Recent events (2)
  • — I (S) $8191.8
  • — Z (S) $13653

1910.147 C05 II D

Serious Gravity 10 1 instance 12 exposed
Issued
Mar 12, 2021
Abate by
Apr 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(5)(ii)(D):Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  (a) On or about November 20, 2020 and times prior thereto; in Plant 1, the Sacmi Press dryer 3 exit  elevator system control board tows 22 and 23, the employer did not ensure locks and tags indicate the identity of employees applying the lockout devices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 10 4 instances 20 exposed
Issued
Mar 12, 2021
Abate by
Apr 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about October 26, 2020, and times prior thereto, the employer developed a written energy control procedure for cleaning, maintenance, conducting dryer chain adjustments, unjamming floor tiles, and other servicing activities. The employer did not affix a lockout or tagout device when performing cleaning, unjamming and other maintenance activities to isolate the hazardous mechanical energy (i.e. gravity). This practice exposed employees to moving machine parts of the following equipment:   (a) In Plant 1, in the Sacmi Press dryer 3 exit elevator and dryer table, counterweight chain; (b) In Plant 1, in the Sacmi Press dryer 4 exit elevator and dryer table,  counterweight chain; (c) In Plant 1, in the  Sacmi Press dryer 5 exit elevator and dryer table counterweight chain; (d) In Plant 1, in the Sacmi Press dryer 6 exit elevator and dryer table counterweight chain.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D06

Serious Gravity 10 4 instances 20 exposed
Issued
Mar 12, 2021
Abate by
Apr 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(6):Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employees did not verify that isolation and deenergization of the machine or equipment had been accomplished:  On or about October 26, 2020, and times prior thereto, the employer developed a written energy control procedure for cleaning, maintenance, conducting dryer chain adjustments, unjamming floor tiles, and other servicing activities. The employer did not ensure the authorized employees verified that the hazardous mechanical energy (i.e. gravity) had locked out or tagged out for the following equipment:     (a) In Plant 1, in the Sacmi Press dryer 3 exit elevator and dryer table, counterweight chain; (b) In Plant 1, in the Sacmi Press dryer 4 exit elevator and dryer table,  counterweight chain; (c) In Plant 1, in the  Sacmi Press dryer 5 exit elevator and dryer table counterweight chain; (d) In Plant 1, in the Sacmi Press dryer 6 exit elevator and dryer table counterweight chain.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Dal-Tile Corporation's full OSHA safety record →