Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EUROFINS TESTING TESTAMERICA, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EUROFINS TESTING TESTAMERICA, INC. in 10 HAZELWOOD DRIVE, BUFFALO, NY 14228 (NAICS 541380). OSHA activity number 344999925.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eurofins Testing Testamerica, INC. — free Get an email when a new federal OSHA severe-injury report for Eurofins Testing Testamerica, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10 HAZELWOOD DRIVE
City
BUFFALO
State
NY
ZIP
14228
Mailing
10 HAZELWOOD DRIVE, BUFFALO, NY 14228
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541380
Employees
67
Ownership type
A

6 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 26, 2021
Abate by
Mar 31, 2021
Penalty
Initial $7,802 · Current $7,802
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Metals Digestions - On or about 10/27/20, two SC100 HotBlocks were plugged into a relocatable power tap surge protective device, Tripp-Lite model no. TLP 808, operating at 120 volts and 15 amperes.  Each SC100 HotBlock operates at  120 volts and 9 amperes.  The power tap was plugged into a dual outlet receptacle.  HotBlocks are not to be used as a substitute for permanent wiring.  HotBlocks were not used or installed in accordance with instructions in the listing or labeling.  b) Metals Digestions - On or about 10/27/20, Two SC100 HotBlocks were plugged into a relocatable power tap surge protective device, Tripp-Lite model no. TLP 808, operating at 120 volts and 15 amperes.  Each SC100 HotBlock operates at  120 volts and 9 amperes.  The power tap was plugged into a dual outlet receptacle.   Employees were using the power tap switch to turn the HotBlocks on and off.   HotBlocks were not used or installed in accordance with instructions in the listing or labeling.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $7802
  • — Z (S) $7802

1910.1052 D01 II B

Other-than-serious Gravity 5 1 instance 7 exposed
Issued
Feb 26, 2021
Abate by
Mar 31, 2021
Penalty
Initial $7,802 · Current $3,901 Reduced
29 CFR  1910.1052(d)(1)(ii)(B):The employer did not determine each employee's exposure by taking personal breathing zone air samples that are representative of each employee's exposure:Note:  This paragraph does not apply to conditions described in 1910.1052(d)(2)(i) - (iii)  a) Organics Prep laboratory - On or about 11/3/2020, an employee uses methylene chloride to clean soil samples during Herbicide Extraction; Soil EPA Method 8151A.  The employer has not taken one or more personal breathing zone air samples which indicate the highest likely 15-minute exposures for at least one employee in each job classification in a work area in each work shift.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $3901
  • — Z (S) $7802

1910.1052 F03 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Feb 26, 2021
Abate by
Apr 12, 2021
Penalty
Initial $7,802 · Current $0 Reduced
29 CFR  1910.1052(f)(3)(i): The employer did not implement procedures to detect leaks of methylene chloride in the workplace:  a) Organics Prep laboratory - On or about 11/3/2020, an employee uses methylene chloride to clean soil samples during Herbicide Extraction: Soil EPA Method 8151A.   The employer did not implement procedures to detect leaks of methylene chloride in the workplace.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $7802

1910.1450 D04

Other-than-serious 1 instance 3 exposed
Issued
Feb 26, 2021
Abate by
Mar 31, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1450(d)(4): The employer did not within 15 working days after the receipt of any monitoring results of laboratory employees' exposures to any substance regulated by a standard, notify the employees of these results in writing either individually or by posting results in an appropriate location that was accessible to employees:   a) Laboratory - On or about 11/3/2020 and ongoing, employees working in the Wet Chemistry Lab, Metals Digestion, Metals Analysis lab were monitoring for Hydrochloric Acid, Nitric Acid, Sulfuric Acid, and Methylene Chloride on 12/27/18, 11/8/2019, and 9/3/2020.   The employer did not notify employees of monitoring results withing 15 working days after the receipt of any monitoring results.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1450 G01 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 26, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1450(g)(1)(i): Employees who had developed signs or symptoms associated with a hazardous chemical to which the employee could have been exposed in the laboratory, were not provided an opportunity to receive an appropriate medical examination:   a) Organics Prep laboratory - On or about 11/3/2020 and ongoing, an employee working in the lab developed signs and symptoms.   The employer did not provided an opportunity to receive an appropriate medical examination.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1052 D01 II B

Other-than-serious Gravity 5 1 instance 7 exposed
Issued
Feb 26, 2021
Abate by
Mar 31, 2021
Penalty
Initial $7,802 · Current $0 Reduced
29 CFR  1910.1052(d)(1)(ii)(B):The employer did not determine each employee's exposure by taking personal breathing zone air samples that are representative of each employee's exposure: Note:  This paragraph does not apply to conditions described in 1910.1052(d)(2)(i) - (iii).  a) Organics Prep laboratory - On or about 11/3/2020, an employee uses methylene chloride to clean soil samples during Herbicide Extraction: Soil EPA Method 8151A.  The employer has not taken one or more personal  breathing zone air samples which indicate the highest likely 15-minute exposures for at least one employee in each job classification in a work area in each work shift.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $7802

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344999925.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.