Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ISPICE, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ISPICE, LLC in 6450 HIGHWAY 43, JACKSON, AL 36545 (NAICS 311942). OSHA activity number 345003057.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ispice, LLC — free Get an email when a new federal OSHA severe-injury report for Ispice, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ISPICE, LLC
Site address
6450 HIGHWAY 43
City
JACKSON
State
AL
ZIP
36545
Mailing
6450 HIGHWAY 43, JACKSON, AL 36545
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311942
Employees
70
Ownership type
A

10 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 19, 2021
Abate by
May 6, 2021
Penalty
Initial $9,557 · Current $6,433 Reduced
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) Patterson Middle Spice Mixer Machine, SN: CA9777, Company number IS/ID#MXR-MIX01-04:  On or about October 27, 2020 ,  the employer exposed employees to potential hazardous energies in that employees were required to clean the spice mixer machine  without first affixing a lockout device on the machines isolating device to secure the machine from the energy source.
Recent events (2)
  • — I (S) $6433
  • — Z (S) $9557

1910.178 L01 I

Serious Gravity 10 1 instance 70 exposed
Issued
Apr 19, 2021
Abate by
May 6, 2021
Penalty
Initial $9,557 · Current $6,433 Reduced
29 CFR  1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a)  Shop Area; On or about October 27, 2020: the employer exposed employees to struck-by hazards in that employees were allowed to operate a powered industrial truck without the employer first ensuring the employee was competent to operate the equipment as demonstrated by the completion of the required training and evaluation specified by the regulation.
Recent events (2)
  • — I (S) $6433
  • — Z (S) $9557

1910.178 P01

Serious Gravity 10 1 instance 70 exposed
Issued
Apr 19, 2021
Abate by
May 6, 2021
Penalty
Initial $9,557 · Current $6,433 Reduced
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    a)  Shop Area; On or about October 27, 2020: the employer exposed employees to crushed-by hazards in that employees were allowed to operate a powered industrial truck that had a damaged seatbelt.
Recent events (2)
  • — I (S) $6433
  • — Z (S) $9557

1910.212 A01

Serious Gravity 10 3 instances 4 exposed
Issued
Apr 19, 2021
Abate by
May 6, 2021
Penalty
Initial $9,557 · Current $6,433 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Middle Spice Mixer Machine:  On or about October 27, 2020 , the employer exposed employees to amputation hazards while adding spice to the 150 inch x 55 inch mixer with two 45 inch x 55 inch openings was not guarded at its point of operation (Mixing blades) exposing employees to the rotating portion of the mixer.
Recent events (2)
  • — I (S) $6433
  • — Z (S) $9557

1910.303 B07 IV

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 19, 2021
Penalty
Initial $9,557 · Current $6,433 Reduced
29 CFR  1910.303(b)(7)(iv): Electric equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  a) Middle Spice Mixer Machine:  On or about October 27, 2020 , the employer exposed employees to struck-by hazards in that the stop button for the middle mixer was damaged (the red upper portion was missing on the switch).
Recent events (2)
  • — I (S) $6433
  • — Z (S) $9557

1910.305 B02 I

Serious Gravity 10 5 instances 4 exposed
Issued
Apr 19, 2021
Penalty
Initial $9,557 · Current $6,433 Reduced
29 CFR  1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) mixing area upper catwalk in front of mixer number 3; On or about October 27, 2020: the employer exposed employees to electrical hazards in that employees were allowed to walk and work and access a duplex outlet that did not have a cover.  b) mixing area upper catwalk in front of stairway access; On or about October 27, 2020: the employer exposed employees to electrical hazards in that employees were allowed to walk and work and access electrical junction box where 3 conduits intersected that did not have a cover.  c) mixing area upper catwalk in front of mixer number 2; On or about October 27, 2020: the employer exposed employees to electrical hazards in that employees were allowed to walk and work and access a single pole receptacle and a duplex ground fault circuit interrupter (GFCI) receptacle that did not have a cover.  d) mixing area upper catwalk in front of mixer number 1; On or about October 27, 2020: the employer exposed employees to electrical hazards in that employees were allowed to walk and work and access a single receptacle outlet that did not have a cover.  e) mixing area upper below the catwalk area; On or about October 27, 2020: the employer exposed employees to electrical hazards in that employees were allowed to walk and work and access a duplex receptacle outlet that did not have a cover.
Recent events (2)
  • — I (S) $6433
  • — Z (S) $9557

1910.334 A02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 19, 2021
Penalty
Initial $6,827 · Current $4,797 Reduced
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  a) mixing area; on or about October 27, 2020: the employer exposed employees to electrical shock hazards by allowing employees to utilize a 120 V fan with a flexible cord with an exposed splice in cord.
Recent events (2)
  • — I (S) $4797
  • — Z (S) $6827

1910.147 C04 I

Repeat Gravity 10 3 instances 8 exposed
Issued
Apr 19, 2021
Abate by
May 6, 2021
Penalty
Initial $19,114 · Current $11,863 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Patterson Middle Spice Mixer Machine, SN: CA9777, Company number IS/ID#MXR-MIX01-04:  On or about October 27, 2020 ,  the employer exposed employees to mechanical, and electrical hazards by not providing an energy control procedure to lock out/tag out the spice mixer machine.    b) Day Spice Mixer Machine, Company number IS/ID#MXR-MIX03-04:  On or about October 27, 2020, the employer exposed employees to mechanical, pneumatic and electrical hazards by not providing an energy control procedure to lock out/tag the Spice mixer machine.    c) Spice Mixer Machine, Company Number IS/ID#MXR-MIX02-04:  On or about October 27, 2020 , the employer exposed employees to mechanical, pneumatic and electrical hazards by not providing an energy control procedure to lock out/tag the spice mixer machine.  iSpice Foods Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1302493, citation number 1 item number 2a and was affirmed as a final order on 7/18/2018, with respect to a workplace located at 6450 US 43 Jackson, AL 36545.
Recent events (2)
  • — I (R) $11863
  • — Z (R) $19114

1910.147 C07 I

Repeat Gravity 10 2 instances 8 exposed
Issued
Apr 19, 2021
Abate by
May 6, 2021
Penalty
Initial $19,114 · Current $11,863 Reduced
29 CFR  1910.147(c)(7)(i):The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) Maintenance Department:  On or about October 27, 2020, the employer exposed employees to mechanical and electrical hazards by not ensuring authorized lock out/tag out training was conducted for employees engaged in servicing and maintenance of equipment such as but not limited to the spice mixing equipment.  b) Mixing Department:  On or about October 27, 2020, the employer exposed employees to mechanical and electrical hazards by not ensuring authorized lock out/tag out training was conducted for employees engaged in the cleaning of equipment such as but not limited to the spice mixing equipment.  iSpice Foods Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(7)(i)(A), which was contained in OSHA inspection number 1302493, citation number 1 item number 2c and was affirmed as a final order on 7/18/2018, with respect to a workplace located at 6450 US 43 Jackson, AL 36545.
Recent events (2)
  • — I (R) $11863
  • — Z (R) $19114

1910.305 B01 I

Repeat Gravity 10 2 instances 4 exposed
Issued
Apr 19, 2021
Penalty
Initial $19,114 · Current $11,863 Reduced
29 CFR  1910.305(b)(1)(i):Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions and/or opening openings through which conductors enter where not effectively closed:  a) Electrical disconnect below spice mixing catwalk: On or about October 27, 2020, the employer exposed employees to electrical burns, shock and fire hazards from a 120 V 20 amp electrical circuit entering an electrical disconnect that was not protected from abrasion.  a) spice mixing area upper catwalk in front of mixer 2: On or about October 27, 2020, the employer exposed employees to electrical burns, shock and fire hazards from a 120 V 20 amp electrical circuit traveling through a separated section of electrical conduit that was not protected from abrasion.  iSpice Foods Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1302493, citation number 2, item number 3 and was affirmed as a final order on 7/18/2018, with respect to a workplace located at 6450 US 43 Jackson, AL 36545.
Recent events (2)
  • — I (R) $11863
  • — Z (R) $19114

View Ispice, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345003057.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.