Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARTURO QUINTANA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARTURO QUINTANA in 1017 BILLY LANE, ALLEN, TX 75013 (NAICS 238130). OSHA activity number 345003321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arturo Quintana — free Get an email when a new federal OSHA severe-injury report for Arturo Quintana is published. One employer, no account, unsubscribe in one click.
Establishment
ARTURO QUINTANA
Site address
1017 BILLY LANE
City
ALLEN
State
TX
ZIP
75013
Mailing
11457 DENNY RD. APT. 2133, DALLAS, TX 75229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.25 A

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $1,735 · Current $1,735
29 CFR 1926.25(a): During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:  (a) On or about October 30, 2020 employees were performing framing operations were exposed to wooden construction debris with protruding nails at the jobsite.
Recent events (1)
  • — Z (S) $1735

1926.100 A

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $1,735 · Current $1,735
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  (a) On or about October 30, 2020 employees were exposed to falling and flying objects and did not wear protective helmets.
Recent events (1)
  • — Z (S) $1735

1926.102 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $2,313 · Current $2,313
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents.  (a) On or about October 30, 2020 employees were performing framing operations and used pneumatic nail guns without the use of protective eyewear. Employees were exposed to eye injuries.
Recent events (1)
  • — Z (S) $2313

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   (a) On or about October 30, 2020 , employees were exposed to a fall hazard of 10-feet to the ground below.
Recent events (1)
  • — Z (S) $4048

1926.1052 C01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $2,892 · Current $2,892
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:   (a) On or about October 30, 2020,  on the staircase of the residential home, the employer did not ensure that stairways having four or more risers rising more than 30 inches were equipped with a stair rail system along each unprotected side or edge to protect employees from falling approximately 10- feet to the concrete floor below.
Recent events (1)
  • — Z (S) $2892

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345003321.