Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DOLLAR TREE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DOLLAR TREE in 611 E CHESTNUT ST., JUNCTION CITY, KS 66441 (NAICS 453998). OSHA activity number 345004063.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dollar Tree — free Get an email when a new federal OSHA severe-injury report for Dollar Tree is published. One employer, no account, unsubscribe in one click.
Establishment
DOLLAR TREE
Site address
611 E CHESTNUT ST.
City
JUNCTION CITY
State
KS
ZIP
66441
Mailing
500 VOLVO PARKWAY, CHESAPEAKE, VA 23320
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
10000
Ownership type
A

7 citations on file for this inspection.

1910.23 C08

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 19, 2021
Abate by
Apr 14, 2021
Penalty
Initial $10,728 · Current $10,728
29 CFR  1910.23(c)(8): The employer did not ensure that the cap and top step of a stepladder that are not used as steps:  Employees engaged in material handling activities using an 8 foot A-frame ladder, were exposed to fall hazards of approximately 8 feet in that they were using the top step of ladder.
Recent events (3)
  • — W (S) $10728
  • — C (S) $10728
  • — Z (S) $10728

1910.28 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 19, 2021
Abate by
Apr 14, 2021
Penalty
Initial $10,728 · Current $10,728
29 CFR  1910.28(b)(1)(i):The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  Employees engaged in material handing activities were exposed to fall hazards of 9 feet in that walking working surface of the mezzanine did not have a fall protection system.
Recent events (3)
  • — W (S) $10728
  • — C (S) $10728
  • — Z (S) $10728

1910.36 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 19, 2021
Abate by
Apr 14, 2021
Penalty
Initial $7,802 · Current $7,802
29 CFR  1910.36(g)(2):Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:   Employees engaged in material handling activities were exposed to trip and burn hazards in that the aisle leading to the exit discharge was not maintained at least 28 inches in width.
Recent events (3)
  • — W (S) $7802
  • — C (S) $7802
  • — Z (S) $7802

1910.38 B

Serious Gravity 1 1 instance 7 exposed
Issued
Mar 19, 2021
Abate by
Apr 14, 2021
Penalty
Initial $5,851 · Current $5,851
29 CFR  1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:   Employees engaged in cashier and material handling activities were exposed to struck by, burn, laceration, contusion, and fractures hazards in that a written workplace emergency action plan was not implemented.
Recent events (3)
  • — W (S) $5851
  • — C (S) $5851
  • — Z (S) $5851

1910.303 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 19, 2021
Abate by
Apr 14, 2021
Penalty
Initial $6,436 · Current $6,436
29 CFR  1910.303(b)(1):Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  Employees engaged in material handling activities were exposed to electric shock in that the electrical outlet had damaged insulation.
Recent events (3)
  • — W (S) $6436
  • — C (S) $6436
  • — Z (S) $6436

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 19, 2021
Abate by
Apr 14, 2021
Penalty
Initial $6,436 · Current $6,436
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Employees were exposed to fire and electrical hazards in that a surge protector was plugged into a power strip which was providing power to a  computer monitor, computer hard drive, phone, computer router, tellermate, miniature fan, RF gun, and RF charger.
Recent events (3)
  • — W (S) $6436
  • — C (S) $6436
  • — Z (S) $6436

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 19, 2021
Abate by
Apr 14, 2021
Penalty
Initial $12,873 · Current $12,873
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Employees engaged in retail activities were exposed to fire and electrical shock hazards in that the flexible cord used to supply power to the Black and Decker Coffee Pot was used in lieu of fixed wiring.
Recent events (3)
  • — W (S) $12873
  • — C (S) $12873
  • — Z (S) $12873

View Dollar Tree's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345004063.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.