Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GOODWIN ARCHITECTURAL MILLWORK, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of GOODWIN ARCHITECTURAL MILLWORK, LLC in 1092 W ATLANTA ST SE BLDG 400, MARIETTA, GA 30060 (NAICS 321918). OSHA activity number 345007041.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Goodwin Architectural Millwork, LLC — free Get an email when a new federal OSHA severe-injury report for Goodwin Architectural Millwork, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1092 W ATLANTA ST SE BLDG 400
City
MARIETTA
State
GA
ZIP
30060
Mailing
1092 W ATLANTA ST SE BLDG 400, MARIETTA, GA 30060
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
12
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 12, 2021
Abate by
May 6, 2021
Penalty
Initial $3,316 · Current $1,990 Reduced
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   a)Throughout the facility: On or about November 5, 2020, and at times prior, employees were exposed to amputation hazards, in that the employer did not develop and implement a control of hazardous energy program where employees perform servicing and maintenance on machines including, but not limited to, table saws, a panel saw and a CNC machine.
Recent events (2)
  • — I (S) $1989.6
  • — Z (S) $3316

1910.178 L02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 12, 2021
Abate by
May 6, 2021
Penalty
Initial $2,653 · Current $1,592 Reduced
29 CFR  1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.  a) Throughout the facility: On or about November 5, 2020, and at times prior, employees were exposed to struck-by hazards, in that the employer did not provide powered industrial truck operator training and evaluations meeting the requirements of the standard for content and frequency where employees operate the "Hyster" model E60XM2 electric forklift (Serial No. F108V20971X).
Recent events (2)
  • — I (S) $1591.8
  • — Z (S) $2653

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Apr 12, 2021
Abate by
May 6, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Production Area: On or about November 5, 2020, and at times prior, employees were exposed to chemical hazards, in that the employer had not developed and implemented a written hazard communication program for employees working with chemicals including, but not limited to, High Performance Spray Adhesive PB938- Clear.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 2 exposed
Issued
Apr 12, 2021
Abate by
May 6, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(1):  The employer did not have a safety data sheet in the workplace for each hazardous chemical used.  a) Production Area: On or about November 5, 2020, and at times prior, employees were exposed to chemical hazards, in that the employer had not provided a safety data sheet for each chemical employees used  including, but not limited to, High Performance Spray Adhesive PB938- Clear.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Goodwin Architectural Millwork, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345007041.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.