MIAMI, FL —
OSHA Inspection: GLASGOW EQUIPMENT SERVICE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GLASGOW EQUIPMENT SERVICE, INC. in 15000 COLLINS AVENUE, MIAMI, FL 33154 (NAICS 237120). OSHA activity number 345007389.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLASGOW EQUIPMENT SERVICE, INC.
- Site address
- 15000 COLLINS AVENUE
- City
- MIAMI
- State
- FL
- ZIP
- 33154
- Mailing
- 4711 N AUSTRIALIAN AVENUE U9, WEST PALM BEACH, FL 33407
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 11
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.146 C05 II C 2
- Issued
- Apr 21, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $3,121 · Current $2,185 Reduced
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(C)(2): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i), but before an employee entered the space, the internal atmosphere was not tested with a calibrated direct-reading instrument for gasoline vapors in the fuel tank: On or about 10/30/2020, at 15000 Collins Avenue, Miami, Florida, the employer did not test the internal atmosphere with a direct reading instrument for gasoline vapors in the fuel tank thereby exposing an employee to the hazard of fuel vapor ignition and burns.
Recent events (2)
- — I (S) $2184.7
- — Z (S) $3121
1910.146 C05 II F
- Issued
- Apr 21, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(F): The atmosphere within the space was not periodically tested as necessary to ensure that the continuous forced air ventilation was preventing the accumulation of a hazardous atmosphere. On or about 10/30/2020, at 15000 Collins Avenue, Miami Beach, Florida, the employer did not ensure the atmosphere in the confined space inside a fuel tanker was monitored for continuous forced air ventilation to prevent a hazardous atmosphere, thus exposing an employee to an flash fire burn hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 D03 VI
- Issued
- Apr 21, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $3,121 · Current $2,185 Reduced
General-duty citation text
29 CFR 1910.146(d)(3)(vi):The employer did not verify that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry. On or about 10/30/2020, at 15000 Collins Avenue, Miami, Florida, the employer failed to ensure that conditions in the permit space were acceptable for the duration of the authorized entry thereby exposing the employee to the hazard of asphyxiation.
Recent events (2)
- — I (S) $2184.7
- — Z (S) $3121
More inspections in this industry (NAICS 237120)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345007389.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.