Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KRO ENERGY PRODUCTS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KRO ENERGY PRODUCTS LLC in 13019 CROCKETT MARTIN, CONROE, TX 77306 (NAICS 332999). OSHA activity number 345011803.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KRO Energy Products LLC — free Get an email when a new federal OSHA severe-injury report for KRO Energy Products LLC is published. One employer, no account, unsubscribe in one click.
Site address
13019 CROCKETT MARTIN
City
CONROE
State
TX
ZIP
77306
Mailing
13019 CROCKETT MARTIN, CONROE, TX 77306
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
8
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $2,926 · Current $2,926
29 CFR  OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees.  On or about November 5, 2020, and times prior thereto, in the Main Shop Area, employees were required to stock and remove products and other miscellaneous items from steel storage racks that were not secured to the floor.
Recent events (1)
  • — Z (S) $2926

1910.106 D03 II B

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $2,926 · Current $2,926
29 CFR  1910.106(d)(3)(ii)(b):The bottom, sides, and/or tops of wooden cabinets were not constructed of an approved grade of plywood at least 1 inch in thickness, that would  prevent it from breaking down or delaminating under fire conditions:  On or about November 5, 2020, and at times prior thereto, in the Storage Room located in the Main Shop Area, employees were exposed to a fire hazard when flammable liquids were stored in a job-made wooden storage cabinet that was not constructed with a bottom, sides, and/or tops of an approved grade of plywood at least 1 inch in thickness.
Recent events (1)
  • — Z (S) $2926

1910.151 C

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $2,926 · Current $2,926
29 CFR  1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or about November 5, 2020, and times prior thereto, employees throughout the facility were exposed to chemical hazards while using and/or working around corrosive chemicals without having access to suitable facilities for quick drenching or flushing of the eyes and body for immediate emergency use.
Recent events (1)
  • — Z (S) $2926

1910.178 Q01

Serious Gravity 1 1 instance 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $1,755 · Current $1,755
29 CFR  1910.178(q)(1):Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  On or about November 5, 2020, and times prior thereto, throughout the facility, a Hyster forklift was not taken out of service after it was discovered that the forklift had an inoperative horn.
Recent events (1)
  • — Z (S) $1755

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about November 5, 2020, and at times prior thereto, in the Main Shop Area, an employee was exposed to struck-by and caught-by hazards when operating a Jet HBS-916W horizontal band saw without a portion of the blade being guarded.
Recent events (1)
  • — Z (S) $4096

1910.1200 E01

Other-than-serious 1 instance 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about November 5, 2020, and times prior thereto, in the Shop Area of the facility where employees were required  handle and/or work around chemicals before a written hazard communication program had been developed and implemented.
Recent events (1)
  • — Z (O) $0

1910.157 E01

Other-than-serious 1 instance 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(1):The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  On or about November 5, 2020, and times prior thereto, employees were potentially exposed to fire hazards throughout the facility while operating machines and grinders without portable fire extinguishers that had been inspected.
Recent events (1)
  • — Z (O) $0

1910.178 A06

Other-than-serious 2 instances 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.178(a)(6):The employer did not ensure that all nameplates or markings were maintained in a legible condition:  On or about November 5, 2020, and at times prior thereto, the employer did not ensure that nameplates or markings and load capacity placard was maintained in a legible condition:  a.  On the Nissan Optimum 50 powered industrial vehicle that was in use by the employees. b.  On the Hyster powered industrial vehicle that was in use by the employees.
Recent events (1)
  • — Z (O) $0

1910.178 L01 I

Other-than-serious 1 instance 8 exposed
Issued
Mar 23, 2021
Abate by
Apr 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about November 5, 2020, and at times prior thereto, employees working at the facility were required to operate forklifts to move products and material without being  trained and evaluated by the employer, to ensure they could do so safely.
Recent events (1)
  • — Z (O) $0

View KRO Energy Products LLC's full OSHA safety record →