SAUSALITO, CA —
OSHA Inspection: BONNIE L. CARPENTER CONSTRUCTION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BONNIE L. CARPENTER CONSTRUCTION in 18 MAIN DOCK, SAUSALITO, CA 94965 (NAICS 236115). OSHA activity number 345013627.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BONNIE L. CARPENTER CONSTRUCTION
- Site address
- 18 MAIN DOCK
- City
- SAUSALITO
- State
- CA
- ZIP
- 94965
- Mailing
- 5921 VALLEJO STREET, EMERYVILLE, CA 94608
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.1051 A
- Issued
- Mar 25, 2021
- Penalty
- Initial $2,341 · Current $1,639 Reduced
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. Construction Project, 18 Main Dock, Rd. 3 - A black, foldable chair was used in lieu of stairs to gain access to the main point of entry to the interior of the project. Employees are exposed to slip, trip, and fall hazards.
Recent events (2)
- — I (S) $1638.7
- — Z (S) $2341
1926.451 B04
- Issued
- Mar 25, 2021
- Penalty
- Initial $1,755 · Current $1,229 Reduced
General-duty citation text
29 CFR 1926.451(b)(4):Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). Construction Project, 18 Main Dock, Rd. 3 - In the following locations, scaffold planking did not extend 6 " past the centerline support as required. The employees are exposed to potential fall hazards. 1. 1st level scaffold, NE corner - the planking extended 3.5" 2. 1st level scaffold, gangway - the planking extended 4.5"
Recent events (2)
- — I (S) $1228.5
- — Z (S) $1755
1926.451 G04
- Issued
- Mar 25, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4):Guardrail systems installed to meet the requirements of this section shall comply with the following provisions (guardrail systems built in accordance with Appendix A to this subpart will be deemed to meet the requirements of paragraphs (g)(4)(vii), (viii), and (ix) of this section): Construction Project, 18 Main Dock, Rd. 3 - The following inadequacies were observed on A-1, Modular Series scaffolding erected at the worksite. Employees were exposed to fall hazards up to 12'. 1. Main deck level, facing front from access point - An entire section (approximately 8 feet) of standard guardrails, including bracing, was removed to allow onboarding of lumber; 12' fall hazard to ground level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.106 C
- Issued
- Mar 25, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.106(c): Ring buoys with at least 90 feet of line shall be provided and readily available for emergency rescue operations. Distance between ring buoys shall not exceed 200 feet. Construction Project, 18 Main Dock, Rd. 3 - A ring buoy was not provided at the work site where employees are working near or over water. The equipment is required for rescue if an employee falls into water.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.405 G01 III D
- Issued
- Mar 25, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(1)(iii)(D):Where attached to building surfaces. Construction Project, 18 Main Dock, Rd. 3, main deck, interior - An orange flexible cord used to power hand tools was tacked to the wall surface with a nail. Employees were exposed to potential electrical hazards.