Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BONNIE L. CARPENTER CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BONNIE L. CARPENTER CONSTRUCTION in 18 MAIN DOCK, SAUSALITO, CA 94965 (NAICS 236115). OSHA activity number 345013627.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bonnie L. Carpenter Construction — free Get an email when a new federal OSHA severe-injury report for Bonnie L. Carpenter Construction is published. One employer, no account, unsubscribe in one click.
Site address
18 MAIN DOCK
City
SAUSALITO
State
CA
ZIP
94965
Mailing
5921 VALLEJO STREET, EMERYVILLE, CA 94608
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.1051 A

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 25, 2021
Penalty
Initial $2,341 · Current $1,639 Reduced
29 CFR  1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.  Construction Project, 18 Main Dock, Rd. 3 -  A black, foldable chair was used in lieu of stairs to gain access to the main point of entry to the interior of the project.   Employees are exposed to slip, trip, and fall hazards.
Recent events (2)
  • — I (S) $1638.7
  • — Z (S) $2341

1926.451 B04

Serious Gravity 1 2 instances 5 exposed
Issued
Mar 25, 2021
Penalty
Initial $1,755 · Current $1,229 Reduced
29 CFR  1926.451(b)(4):Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).  Construction Project, 18 Main Dock, Rd. 3 - In the following locations, scaffold planking did not extend 6 " past the centerline support as required.  The employees are exposed to potential fall hazards.  1. 1st level scaffold, NE corner - the planking extended 3.5" 2. 1st level scaffold, gangway - the planking extended 4.5"
Recent events (2)
  • — I (S) $1228.5
  • — Z (S) $1755

1926.451 G04

Serious Gravity 5 5 instances 5 exposed
Issued
Mar 25, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4):Guardrail systems installed to meet the requirements of this section shall comply with the following provisions (guardrail systems built in accordance with Appendix A to this subpart will be deemed to meet the requirements of paragraphs (g)(4)(vii), (viii), and (ix) of this section):  Construction Project, 18 Main Dock, Rd. 3 - The following inadequacies were observed on A-1,  Modular Series scaffolding erected at the  worksite.  Employees were exposed to fall hazards up to 12'.  1.  Main deck level, facing front from access point - An entire section (approximately 8 feet) of standard guardrails, including bracing, was removed to allow onboarding of lumber; 12' fall hazard to ground level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.106 C

Other-than-serious 1 instance 5 exposed
Issued
Mar 25, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.106(c): Ring buoys with at least 90 feet of line shall be provided and readily available for emergency rescue operations. Distance between ring buoys shall not exceed 200 feet.  Construction Project, 18 Main Dock, Rd. 3 - A ring buoy was not provided at the work site where employees are working near or over water.  The equipment is required for rescue if an employee falls into water.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G01 III D

Other-than-serious 1 instance 2 exposed
Issued
Mar 25, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.405(g)(1)(iii)(D):Where attached to building surfaces.  Construction Project, 18 Main Dock, Rd. 3, main deck, interior - An orange flexible cord used to power hand tools was tacked to the wall surface with a nail.  Employees were exposed to potential electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345013627.