MASSILLON, OH —
OSHA Inspection: OHIO'S ROOF SPECIALIST LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OHIO'S ROOF SPECIALIST LLC in 8648 ASHMEDE CT CIR NW, MASSILLON, OH 44646 (NAICS 238160). OSHA activity number 345014302.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OHIO'S ROOF SPECIALIST LLC
- Site address
- 8648 ASHMEDE CT CIR NW
- City
- MASSILLON
- State
- OH
- ZIP
- 44646
- Mailing
- 934 4TH ST, CANTON, OH 44703
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Dec 14, 2020
- Penalty
- Initial $2,313 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about November 3, 2020, during the installation of roofing material at the job site located at 8648 Ashmede CT CIR NW, Massillon, Ohio 44646; the employer did not ensure employees working on the roof of a single family home were protected from possible danger of eye injury from impact, or from flying objects from the employees installing roofing material.
Recent events (3)
- — F (S) $1250
- — C (S) $2313
- — Z (S) $2313
1926.1053 B01
- Issued
- Dec 14, 2020
- Penalty
- Initial $2,313 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about November 3, 2020, during the installation of roofing material at the job site located at 8648 Ashmede CT CIR NW, Massillon, Ohio 44646; during the installation of roofing material on a residential roof, the employer did not ensure portable ladders extend 3 feet above the upper landing surface.
Recent events (3)
- — F (S) $1250
- — C (S) $2313
- — Z (S) $2313
1926.501 B13
- Issued
- Dec 14, 2020
- Penalty
- Initial $3,470 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about November 3, 2020, during the installation of roofing material at the job site located at 8648 Ashmede CT CIR NW, Massillon, Ohio 44646; the employer did not ensure employees working on a roof of a single family home were protected from a fall of approximately 11.2 feet by utilizing a fall protection system.
Recent events (3)
- — F (S) $1500
- — C (S) $3470
- — Z (S) $3470
More inspections at Ohio'S Roof Specialist LLC
View Ohio'S Roof Specialist LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345014302.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.