Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNRISE TRUCKING & EXCAVATING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNRISE TRUCKING & EXCAVATING LLC in RICKLEFS PL AND STONEBRIDGE RD, KRONENWETTER, WI 54455 (NAICS 237110). OSHA activity number 345020846.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunrise Trucking & Excavating LLC — free Get an email when a new federal OSHA severe-injury report for Sunrise Trucking & Excavating LLC is published. One employer, no account, unsubscribe in one click.
Site address
RICKLEFS PL AND STONEBRIDGE RD
City
KRONENWETTER
State
WI
ZIP
54455
Mailing
207 2ND STREET, MOSINEE, WI 54455
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR  1926.651(c)(2):  Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  On November 6, 2020 at Ricklefs Place and Stonebridge Road in Kronenwetter, Wisconsin, employees were working from inside a trench shield at ten and one-half feet deep without an access/egress ladder installed.
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.   On November 6, 2020 at Ricklefs Place and Stonebridge Road in Kronenwetter, Wisconsin, the employer did not ensure that a competent person was performing frequent and regular inspections that could have recognized the potential struck-by and/or crushing hazards associated with employees working from inside a trench shield at ten and one half feet deep.  Employees were exposed to trenching hazards including the spoil piles within two feet from trench edge, the trench shield positioned below the top edge, no access/egress from the trench, and a trench shield without keeper pins installed for securing the spreader bar pins.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.652 C02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.652(c)(2)(i):  Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer.   a)  On November 6, 2020 at Ricklefs Place and Stonebridge Road in Kronenwetter, Wisconsin, employees were working from inside a trench shield at ten and one half feet prior to securing the spreader bar pins; pins on three spreader bars did not have the keeper pins installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR  1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.   On November 6, 2020 at Ricklefs Place and Stonebridge Road in Kronenwetter, Wisconsin, employees were working from inside a trench shield at ten and one half feet deep without the spoil piles at least two feet back from the trench top edge.
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section.  On November 6, 2020 at Ricklefs Place and Stonebridge Road in Kronenwetter, Wisconsin, employees were working from inside a trench shield at ten and one half feet deep without the top edge extending eighteen inches above the trench.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Sunrise Trucking & Excavating LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345020846.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.