FELTON, DE ·
OSHA Inspection: DELFI CONSTRUCTION, LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of DELFI CONSTRUCTION, LLC in COURSEY'S POINT DEVELOPMENT LOT 188, FELTON, DE 19943 (NAICS 236115). OSHA activity number 345021455.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELFI CONSTRUCTION, LLC
- Site address
- COURSEY'S POINT DEVELOPMENT LOT 188
- City
- FELTON
- State
- DE
- ZIP
- 19943
- Mailing
- 37942 ROOSEVELT AVE, SELBYVILLE, DE 19975
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 15
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1926.50 D01
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $3,121 · Current $1,873 Reduced
General-duty citation text
29 CFR 1926.50(d)(1): First aid supplies were not accessible to the employees at the site a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020; The employer did not provide first aid kit/supplies to employees framing a ranch style home
Recent events (2)
- · I (S) $1872.6
- · Z (S) $3121
1926.150 A01
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $3,121 · Current $1,873 Reduced
General-duty citation text
29 CFR 1926.150(a)(1): The employer did not develop and maintain a fire protection program to be followed throughout all phases of construction and demolition work, and did not provide for the firefighting equiment as specified in this subpart: a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020; The employer did not provide any type of fire protection program to ensure that proper fire protection was addressed and the employees knew what to do in the event of a fire.
Recent events (2)
- · I (S) $1872.6
- · Z (S) $3121
1926.150 C01 I
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof and the travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet: a) Lot 97 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020; The employer did not provide any type of fire extinguishing equipment at the site. The nearest fire department is a volunteer depart and the average response time is 15 minutes in the event of a fire.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 L01 I
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $4,681 · Current $2,809 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i):29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l) (Construction reference 1926.602(d)): a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020; The employer did not provide training to employees conducting framing activities using a Pettibone power industrial to raise wood to elevated levels for roof sheeting.
Recent events (2)
- · I (S) $2808.6
- · Z (S) $4681
1926.501 B14
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening was less than 39 inches (1.0 M) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020, the employer failed to ensure employees conducting framing work on, at, above, or near wall openings, approximately 16 feet above grade, were provided not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system.
Recent events (2)
- · I (S) $3276.6
- · Z (S) $5461
1926.503 A01
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not train each employee who might be exposed to fall hazards to enable them to recognize fall hazards and the procedures to be followed in order to minimize these hazards: a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020, the employer did not train each employee conducting framing work to properly recognize and minimize fall hazards. Abatement Note: The training program must enable the employees to recognize the hazards of falling and must train each employee in the procedures to be followed in order to minimize these hazards. Each employee must be trained by a competent person in the following: 1. The nature of fall hazards in the work area; 2. The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used; 3. The use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used; 4. The role of each employee in the safety monitoring system when this system is used; 5. The limitations on the use of mechanical equipment during the performance of roofing work on low-sloped roofs; 6. The correct procedures for the handling and storage of equipment and materials and the erection of overhead protection; 7. The role of employees in fall protection plans; 8. The standards contained in this subpart. The employer must verify compliance with paragraph (a) of this section by preparing a written certification record that will contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B01
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020; employees conducting framing activities used an aluminum extension ladder that did not extend at least three feet above the upper landing, exposing them to falls approximately 14' above grade.
Recent events (2)
- · I (S) $3276.6
- · Z (S) $5461
1926.1060 A
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $0 · Current $163
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020; The employer did not provide training to employees conducting framing activities using an aluminum extension ladder that did not extend at least three feet above the upper landing, exposing them to falls.
Recent events (2)
- · I (S) $162.63
- · Z (S) $0
1926.1053 B16
- Issued
- Apr 1, 2021
- Abate by
- Apr 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired. a) Lot 188 Coursey's Point Subdivision Felton, DE - On or about November 10, 2020; Portable ladder(s) with defective or faulty components were not identified and withdrawn from service as required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 236115)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345021455.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.