SUPERIOR, WI —
OSHA Inspection: GREAT LAKES ELECTRICAL EQUIPMENT COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GREAT LAKES ELECTRICAL EQUIPMENT COMPANY in 320 BAXTER AVENUE, SUPERIOR, WI 54880 (NAICS 423610). OSHA activity number 345022388.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREAT LAKES ELECTRICAL EQUIPMENT COMPANY
- Site address
- 320 BAXTER AVENUE
- City
- SUPERIOR
- State
- WI
- ZIP
- 54880
- Mailing
- 320 BAXTER AVENUE, SUPERIOR, WI 54880
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423610
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 L01 II
- Issued
- Dec 23, 2020
- Abate by
- Feb 1, 2021
- Penalty
- Initial $3,084 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii):The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: (a) Throughout the facility; Each forklift operator without previous forklift operating experience had not been trained as required by this standard before they were allowed to operate forklifts.
Recent events (2)
- — I (S) $2100
- — Z (S) $3084
1910.178 Q06
- Issued
- Dec 23, 2020
- Abate by
- Feb 1, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(6): Powered industrial trucks were altered so that the relative positions of the various parts were different from what they were when originally received from the manufacturer, by the addition of extra parts not provided by the manufacturer, or by the elimination of any parts without the manufacturer's approval: (a) Throughout the facility; The mast on a Datsun brand forklift was altered by drilling a hole through it and adding/inserting a pin through the mast without approval from the forklift manufacturer. (b) Throughout the facility; The ignition system on a Datsun brand forklift was altered by changing it to a toggle and push button system without approval from the forklift manufacturer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- Dec 23, 2020
- Abate by
- Feb 1, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) Throughout the facility; The employer did not maintain a record to certify that each forklift operator had been trained to operate and had their skills to safely operate forklifts evaluated by this company.