OSHA Inspection: HANWHA AEROSPACE USA CO., LTD.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HANWHA AEROSPACE USA CO., LTD. in 5 MCKEE PLACE, CHESHIRE, CT 06410 (NAICS 336412). OSHA activity number 345024103.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hanwha Aerospace USA CO., LTD. — free Get an email when a new federal OSHA severe-injury report for Hanwha Aerospace USA CO., LTD. is published. One employer, no account, unsubscribe in one click.
Site address
5 MCKEE PLACE
City
CHESHIRE
State
CT
ZIP
06410
Mailing
5 MCKEE PLACE, CHESHIRE, CT 06410
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336412
Employees
258
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 7 exposed
Issued
May 7, 2021
Abate by
Jul 15, 2021
Penalty
Initial $13,653 · Current $9,550 Reduced
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  Facility: The employer did not establish an energy control program that consisted of an energy control procedure, employee training, and/or periodic inspections.
Recent events (2)
  • — I (S) $9550
  • — Z (S) $13653

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2021
Abate by
Jul 15, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Large Turning- Sundstrand VTL:  Adequate and sufficient procedures were not developed, documented and utilized to protect employees from the unexpected activation and movement of the Sundstrand VTL clamp/unclamping device while performing servicing and maintenance activities whereby the guard/cover to the clamp/unclamping was removed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 7, 2021
Abate by
Jul 15, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  Facility: A periodic inspection of the energy control procedures was not conducted and documented at least annually to ensure the procedures and requirements of the energy control standard were being adhered to and followed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 7, 2021
Abate by
Jul 15, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  Facility:  Each authorized employee exposed  to amputations, caught-in hazards,  and electrical shock hazards while performing maintenance and servicing on machines such as, but not limited to, the Sundstrand VTL machine were not provided with comprehensive training to ensure the purpose and function of the energy control program and energy control procedures are understood by each employee and each employee has the required knowledge and skills for the safe application, usage,  and removal of the energy controls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.30 A01

Other-than-serious 1 instance 7 exposed
Issued
May 7, 2021
Abate by
Jul 15, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.30(a)(1): The employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart before any employee is exposed to a fall hazard.   Facility:  Each maintenance employee that utilizes "boom/man- lifts" and are exposed to fall hazards were not trained in the proper and safe use of personal fall protection systems.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345024103.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.