CHESHIRE, CT —
OSHA Inspection: HANWHA AEROSPACE USA CO., LTD.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HANWHA AEROSPACE USA CO., LTD. in 5 MCKEE PLACE, CHESHIRE, CT 06410 (NAICS 336412). OSHA activity number 345024103.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HANWHA AEROSPACE USA CO., LTD.
- Site address
- 5 MCKEE PLACE
- City
- CHESHIRE
- State
- CT
- ZIP
- 06410
- Mailing
- 5 MCKEE PLACE, CHESHIRE, CT 06410
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 258
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- May 7, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $13,653 · Current $9,550 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Facility: The employer did not establish an energy control program that consisted of an energy control procedure, employee training, and/or periodic inspections.
Recent events (2)
- — I (S) $9550
- — Z (S) $13653
1910.147 C04 I
- Issued
- May 7, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Large Turning- Sundstrand VTL: Adequate and sufficient procedures were not developed, documented and utilized to protect employees from the unexpected activation and movement of the Sundstrand VTL clamp/unclamping device while performing servicing and maintenance activities whereby the guard/cover to the clamp/unclamping was removed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- May 7, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Facility: A periodic inspection of the energy control procedures was not conducted and documented at least annually to ensure the procedures and requirements of the energy control standard were being adhered to and followed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- May 7, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: Facility: Each authorized employee exposed to amputations, caught-in hazards, and electrical shock hazards while performing maintenance and servicing on machines such as, but not limited to, the Sundstrand VTL machine were not provided with comprehensive training to ensure the purpose and function of the energy control program and energy control procedures are understood by each employee and each employee has the required knowledge and skills for the safe application, usage, and removal of the energy controls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.30 A01
- Issued
- May 7, 2021
- Abate by
- Jul 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.30(a)(1): The employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart before any employee is exposed to a fall hazard. Facility: Each maintenance employee that utilizes "boom/man- lifts" and are exposed to fall hazards were not trained in the proper and safe use of personal fall protection systems.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336412)