Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WETHERILL INN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WETHERILL INN in 1000 MAIN STREET, KAYENTA, AZ 86033 (NAICS 721110). OSHA activity number 345024889.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wetherill INN — free Get an email when a new federal OSHA severe-injury report for Wetherill INN is published. One employer, no account, unsubscribe in one click.
Establishment
WETHERILL INN
Site address
1000 MAIN STREET
City
KAYENTA
State
AZ
ZIP
86033
Mailing
PO BOX 175 HIGHWAY 163, KAYENTA, AZ 86033
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.157 E03

Other-than-serious 1 instance 3 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check:  FACILITY WIDE - Annual inspections were not performed on fire extinguishers, exposing employees to fire hazards.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 2 instances 3 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) LAUNDRY ROOM - A relocatable power tap had an extension cord plugged into it. The extension cord was powering a wall mounted AC unit, exposing employees to electrical and fire hazards.  b) REFRIGERATOR ROOM - A relocatable power tap was connected in series (daisy chained) with an extension cord to a second relocatable power tap to power two refrigerators, exposing employees to electrical and fire hazards.
Recent events (1)
  • — Z (O) $0

1910.305 G01 IV B

Other-than-serious 1 instance 3 exposed
Issued
Dec 30, 2020
Abate by
Jan 27, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  LAUNDRY ROOM - The flexible power cord to a wall mounted AC unit was run through drywall, exposing employees to fire hazards.
Recent events (1)
  • — Z (O) $0

View Wetherill INN's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345024889.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.