OSHA Inspection: INDIAN HEALTH SERVICE-CHINLE COMP HEALTH CARE FACILITY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INDIAN HEALTH SERVICE-CHINLE COMP HEALTH CARE FACILITY in U.S. 191 & HOSPITAL DR, CHINLE, AZ 86503 (NAICS 622110). OSHA activity number 345026850.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Indian Health Service-Chinle Comp Health Care Facility — free Get an email when a new federal OSHA severe-injury report for Indian Health Service-Chinle Comp Health Care Facility is published. One employer, no account, unsubscribe in one click.
Site address
U.S. 191 & HOSPITAL DR
City
CHINLE
State
AZ
ZIP
86503
Mailing
P.O. DRAWER PH, CHINLE, AZ 86503
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
750
Ownership type
D

3 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 5 3 instances 10 exposed
Issued
Jan 15, 2021
Abate by
Feb 11, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  WAREHOUSE- An evaluation of three powered industrial truck operators' performance was not being conducted at least once every three years, exposing employees to crush-by or struck-by hazards.
Recent events (1)
  • — Z (S) $0

1910.253 B04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 15, 2021
Abate by
Feb 11, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:  COMPRESSED GAS ROOM -  Oxygen cylinder was being stored with other cylinders containing acetylene and nitrous oxide, exposing employees to fire hazards.
Recent events (1)
  • — Z (S) $0

1910.147 C01

Other-than-serious 1 instance 4 exposed
Issued
Jan 15, 2021
Abate by
Feb 11, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  FACILITY WIDE: Employees performed maintenance on machinery to include chillers and boiler equipment. The employer had not established a program consisting of energy control procedures, employee training and inspections to ensure the startup or release of stored energy could not occur while servicing or maintenance, exposing employees to electrical and heat hazards.