OSHA Inspection: HOFA FRAMING & CORNICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HOFA FRAMING & CORNICE in 1403 S. MITCHELL DR., MANSFIELD, TX 76063 (NAICS 238130). OSHA activity number 345048201.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hofa Framing & Cornice — free Get an email when a new federal OSHA severe-injury report for Hofa Framing & Cornice is published. One employer, no account, unsubscribe in one click.
Site address
1403 S. MITCHELL DR.
City
MANSFIELD
State
TX
ZIP
76063
Mailing
1227 BELEW ST., IRVING, TX 75061
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 7, 2020
Abate by
Jan 6, 2021
Penalty
Initial $1,735 · Current $1,735
29 CFR  1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets.   On the west side of the construction site, employees not wearing a hardhats while engaged in framing work were working below other employees above exposing them to being struck by falling objects.
Recent events (1)
  • — Z (S) $1735

1926.102 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 7, 2020
Abate by
Jan 6, 2021
Penalty
Initial $1,735 · Current $1,735
29 CFR  1926.102(a)(1): Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    On the west side of the construction site, employees engaged in framing activities used pneumatic nail guns without wearing eye protection exposing them to struck-by hazards and eye injuries.
Recent events (1)
  • — Z (S) $1735

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 7, 2020
Abate by
Jan 6, 2021
Penalty
Initial $4,048 · Current $4,048
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).     On the west side of the construction site, employees performing framing activities without fall protection were exposed to fall hazards at a height of approximately 16 feet to the ground below.
Recent events (1)
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 7, 2020
Abate by
Jan 6, 2021
Penalty
Initial $2,313 · Current $2,313
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.     On the west side of the construction site, employee used a ladder to access and egress the upper landing area and the ladder did not extend at least 3 feet above the landing surface.  The employees were exposed to potential fall hazards.
Recent events (1)
  • — Z (S) $2313

1926.404 F06

Other-than-serious 1 instance 5 exposed
Issued
Dec 7, 2020
Abate by
Jan 6, 2021
Penalty
Initial $325 · Current $325
29 CFR  1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.      On the west side of the construction site, employees engaged in framing activities utilized an extension cord with the missing ground pin exposing employees to electrical shock hazards.
Recent events (1)
  • — Z (O) $325

1926.503 A02 I

Other-than-serious 1 instance 5 exposed
Issued
Dec 7, 2020
Abate by
Jan 6, 2021
Penalty
Initial $325 · Current $325
29 CFR  1926.503(a)(2)(i): 29 CFR 1926.501(a)(2)(I):  The employer shall ensure that each employee has been trained, as necessary, by a competent person, in the nature of fall hazards in the work area:    On the construction site, the employer did not train the employees on personal fall arrest systems and ladder hazards exposing them to fall hazards.