MANSFIELD, TX —
OSHA Inspection: HOFA FRAMING & CORNICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HOFA FRAMING & CORNICE in 1403 S. MITCHELL DR., MANSFIELD, TX 76063 (NAICS 238130). OSHA activity number 345048201.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOFA FRAMING & CORNICE
- Site address
- 1403 S. MITCHELL DR.
- City
- MANSFIELD
- State
- TX
- ZIP
- 76063
- Mailing
- 1227 BELEW ST., IRVING, TX 75061
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Dec 7, 2020
- Abate by
- Jan 6, 2021
- Penalty
- Initial $1,735 · Current $1,735
General-duty citation text
29 CFR 1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. On the west side of the construction site, employees not wearing a hardhats while engaged in framing work were working below other employees above exposing them to being struck by falling objects.
Recent events (1)
- — Z (S) $1735
1926.102 A01
- Issued
- Dec 7, 2020
- Abate by
- Jan 6, 2021
- Penalty
- Initial $1,735 · Current $1,735
General-duty citation text
29 CFR 1926.102(a)(1): Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. On the west side of the construction site, employees engaged in framing activities used pneumatic nail guns without wearing eye protection exposing them to struck-by hazards and eye injuries.
Recent events (1)
- — Z (S) $1735
1926.501 B13
- Issued
- Dec 7, 2020
- Abate by
- Jan 6, 2021
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). On the west side of the construction site, employees performing framing activities without fall protection were exposed to fall hazards at a height of approximately 16 feet to the ground below.
Recent events (1)
- — Z (S) $4048
1926.1053 B01
- Issued
- Dec 7, 2020
- Abate by
- Jan 6, 2021
- Penalty
- Initial $2,313 · Current $2,313
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. On the west side of the construction site, employee used a ladder to access and egress the upper landing area and the ladder did not extend at least 3 feet above the landing surface. The employees were exposed to potential fall hazards.
Recent events (1)
- — Z (S) $2313
1926.404 F06
- Issued
- Dec 7, 2020
- Abate by
- Jan 6, 2021
- Penalty
- Initial $325 · Current $325
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. On the west side of the construction site, employees engaged in framing activities utilized an extension cord with the missing ground pin exposing employees to electrical shock hazards.
Recent events (1)
- — Z (O) $325
1926.503 A02 I
- Issued
- Dec 7, 2020
- Abate by
- Jan 6, 2021
- Penalty
- Initial $325 · Current $325
General-duty citation text
29 CFR 1926.503(a)(2)(i): 29 CFR 1926.501(a)(2)(I): The employer shall ensure that each employee has been trained, as necessary, by a competent person, in the nature of fall hazards in the work area: On the construction site, the employer did not train the employees on personal fall arrest systems and ladder hazards exposing them to fall hazards.
Recent events (1)
- — Z (O) $325
More inspections at Hofa Framing & Cornice
View Hofa Framing & Cornice's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345048201.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.