OSHA Inspection: SM ROOFING AND SIDING

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SM ROOFING AND SIDING in 207 20TH STREET S, BRIDGETON, NJ 08302 (NAICS 238160). OSHA activity number 345052377.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SM Roofing and Siding — free Get an email when a new federal OSHA severe-injury report for SM Roofing and Siding is published. One employer, no account, unsubscribe in one click.
Site address
207 20TH STREET S
City
BRIDGETON
State
NJ
ZIP
08302
Mailing
449 BRIDGEPORT AVE, OCEANPORT, NJ 07757
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.451 F06

Serious Gravity 10 2 instances 3 exposed
Issued
Jun 3, 2021
Abate by
Jun 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.451(f)(6):Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.  a)  North side, near Northwest corner of house, 207 20th Street South, Brigantine: Employees erected and installed vinyl siding from a mixed component aluminum pump jack scaffold system with an approximate 36 foot high aluminum pole within approximately 10 feet of the 12.47 kV primary, on or about 12/05/2020.  b)  North side, near Northwest corner of house, 207 20th Street South, Brigantine:  Approximate 36 foot high western most Alum-A-Pole employees were trying to lay down,  contacted the approximate 30 foot high 12.47 kV primary, on or about 12/06/2020.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4096

1926.451 F07

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 3, 2021
Abate by
Jun 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:  a)  Construction site, 207 20th Street South, Brigantine:  Pump jack scaffolds were erected and dismantled by employees that were not adequately trained. A competent person did not direct and supervise the work, on or about 12/05/2020.          NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4096

1926.451 G01 VII

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 3, 2021
Abate by
Jun 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:   a)  207 20th Street South, Brigantine, NJ - Employees without adequate fall protection, worked up to approximately 20 feet platform height,  from a mixed component Alum-A-Pole pump jack scaffold system; no fall protection at all at either end of the work platform, on or about 12/06/2020.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4096

1926.452 J02

Serious Gravity 10 2 instances 4 exposed
Issued
Jun 3, 2021
Abate by
Jun 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:  a)  North side, near Northwest corner of house, 207 20th Street South, Brigantine: Employees erected and installed vinyl siding from a mixed component aluminum pump jack scaffold system with an approximate 36 foot high aluminum pole secured at the roof with only one brace approximately 25 feet above ground level, on or about 12/06/2020.  b)  West side, along side of  house, 207 20th Street South, Brigantine:  Employees erected and installed vinyl siding from a mixed component aluminum pump jack scaffold system with an approximate 30 foot high aluminum pole secured at the roof with only one brace approximately 25 feet above ground level, on or about 12/06/2020.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4096

1926.454 A02

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 3, 2021
Abate by
Jun 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.454(a)(2): Employees have not received training in the correct procedures for dealing with electrical hazards and for erecting, maintaining, disassembling the fall protection systems and falling object protection systems being used:  a)  Construction site, 207 20th Street South, Brigantine:  Employees were not trained to recognize the hazards associated with electricity when utilizing scaffolding and the procedures needed to be followed, on or about 12/05/2020.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4096

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 3, 2021
Abate by
Jun 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  North side, near Northwest corner of house, 207 20th Street South, Brigantine: An employee, that removed and installed the triangular bracing for the pump jack poles while on the roof, was not protected from falling approximate 24 feet to the lower level by any type of fall protection system, on or about 12/06/2020.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $4096

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 3, 2021
Abate by
Jun 9, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   a)  Construction site, 207 20th Street South, Brigantine: An employee, that removed and installed triangular bracing while on the roof approximately 24 feet above ground level and without any fall protection, was not adequately trained in the procedures to follow in order to minimize the fall hazards, on or about 12/06/2020.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.