Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DON K CHEVROLET, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DON K CHEVROLET, INC. in 6219 HWY 93 SOUTH, WHITEFISH, MT 59937 (NAICS 441110). OSHA activity number 345056360.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DON K Chevrolet, INC. — free Get an email when a new federal OSHA severe-injury report for DON K Chevrolet, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6219 HWY 93 SOUTH
City
WHITEFISH
State
MT
ZIP
59937
Mailing
PO BOX 1178, WHITEFISH, MT 59937
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
42
Ownership type
A

7 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 42 exposed
Issued
Apr 13, 2021
Abate by
May 7, 2021
Penalty
Initial $5,969 · Current $2,985 Reduced
29 CFR  1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  a)  Don K Chevrolet, Inc. Southwest Automotive Bays, Purple shield Gas Cylinder:  On or about December 8, 2020 and at times prior, employees were exposed to struck by hazards while working around a full shielding gas cylinder (75% Argon, 25% Carbon Dioxide) with regulator attached that was not secured properly.
Recent events (2)
  • — I (S) $2984.5
  • — Z (S) $5969

1910.215 A04

Serious Gravity 1 2 instances 1 exposed
Issued
Apr 13, 2021
Penalty
Initial $4,476 · Current $2,238 Reduced
29 CFR  1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) Don K Chevrolet, Inc. Automotive Repair Shop, Northwest wall: On or about December 8, 2020 and at times prior employees were exposed to caught in hazards while using the abrasive wheel on the JET eight inch bench grinder with the work rest being adjusted to approximately 1/4 inch from the abrasive wheel.  b) Don K Chevrolet, Inc. Automotive Repair Shop, Southeast wall: On or about December 8, 2020 and at times prior employees were exposed to caught in hazards while using the abrasive wheel on the JET eight inch bench grinder with the work rest being adjusted to approximately 1/4 inch from the abrasive wheel.
Recent events (2)
  • — I (S) $2238
  • — Z (S) $4476

1910.215 B09

Serious Gravity 1 2 instances 1 exposed
Issued
Apr 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) Don K Chevrolet, Inc. Automotive Repair Shop, Northwest Wall: On or about December 8, 2020 and at times prior, employees were exposed to struck by hazards while using the abrasive wheel on the JET eight inch bench grinder with the tongue guard being adjusted to approximately 1 inch from the abrasive wheel.  b) Don K Chevrolet, Inc. Automotive Repair Shop, Southeast Wall: On or about December 8, 2020 and at times prior, employees were exposed to struck by hazards while using the abrasive wheel on the JET eight inch bench grinder with the tongue guard being adjusted to approximately 3/4 inch from the abrasive wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 42 exposed
Issued
Apr 13, 2021
Abate by
May 7, 2021
Penalty
Initial $4,476 · Current $2,238 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Don K Chevrolet, Inc. Automotive Repair Shop, Northeast Wall: On or about December 8, 2020 and at times prior, employees were exposed to fire hazards while using a relocatable power tap as a permanent wiring fixture to energize items such as, but not limited to: handheld tool and equipment chargers.
Recent events (2)
  • — I (S) $2238
  • — Z (S) $4476

1910.305 G01 IV A

Serious Gravity 1 1 instance 42 exposed
Issued
Apr 13, 2021
Abate by
May 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Don K Chevrolet, Inc. Automotive Repair Shop Northeast Wall: On or about December 8, 2020 and at times prior, employees were exposed to fire hazards while using a black flexible extension cord as a permanent means of wiring to power a relocatable power tap.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 1 2 instances 42 exposed
Issued
Apr 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(7)(i):Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  a)  Don K Chevrolet, Inc. Southwest Wall, Electrical Junction Box:  On or about December 8, 2020 and at times prior employees were exposed to electrical shock and fire hazards while working near an energized electrical junction box that was missing a knock out.  b)  Don K Chevrolet, Inc. Southeast Wall, Rytec Speed Door Electrical:  On or about December 8, 2020 and at times prior employees were exposed to electrical shock and fire hazards while working near an energized 240 volt electrical knife throw switch that was missing a knock out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 F04

Other-than-serious 1 instance 3 exposed
Issued
Apr 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.29(f)(4): Openings in stair rails. The employer did not ensure that no opening in a stair rail system exceeds 19 inches (48 cm) at its least dimension:  a)  Don K Chevrolet, Inc., Special Tool Mezzanine Stair Rail:  On or about December 8, 2020 and at times prior,  employees were accessing and egressing the Special Tool Room staircase with a gap between the hand rail and step measured at 31 inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View DON K Chevrolet, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345056360.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.