Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WICKMAN CONSTRUCTION AND REAL ESTATE OF WISCONSIN LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WICKMAN CONSTRUCTION AND REAL ESTATE OF WISCONSIN LLC in 9369 THOROUGHFARE ROAD, MINOCQUA, WI 54548 (NAICS 236115). OSHA activity number 345064794.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wickman Construction and Real Estate of Wisconsin LLC — free Get an email when a new federal OSHA severe-injury report for Wickman Construction and Real Estate of Wisconsin LLC is published. One employer, no account, unsubscribe in one click.
Site address
9369 THOROUGHFARE ROAD
City
MINOCQUA
State
WI
ZIP
54548
Mailing
330 STATE HWY 47 WEST, WOODRUFF, WI 54568
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
May 7, 2021
Penalty
Initial $1,755 · Current $1,229 Reduced
29 CFR  1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.   On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, an employee was working on scaffold below employees who were handling tools and metal materials without utilizing head protection equipment.
Recent events (2)
  • — I (S) $1228.5
  • — Z (S) $1755

1926.451 B01 II

Serious Gravity 10 3 instances 4 exposed
Issued
May 7, 2021
Abate by
Jun 14, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR  1926.451(b)(1)(ii):  Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).  a)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, employees were working from fabricated frame scaffolding at twelve and one half feet above surface level without a fully decked platform.  One nineteen inch wide plank was installed between the end frames with a forty inch opening between the plank side edge and upright's cross bracing.  b)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, an employee was working from fabricated frame scaffolding at eleven and one half feet above surface level without a fully decked work platform.  One nineteen inch wide plank was installed between the end frames with a forty inch opening between plank side edge and upright's cross bracing.  c)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, an employee was working from fabricated frame scaffolding at five and one half feet above surface level without a fully decked platform.  One nineteen inch wide plank was installed between the end frames with a forty inch opening between plank side edge and upright's cross bracing.
Recent events (2)
  • — I (S) $2867.2
  • — Z (S) $4096

1926.451 B02

Serious Gravity 10 3 instances 3 exposed
Issued
May 7, 2021
Abate by
Jun 14, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.  On or about December 8, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, employees installing soffit and fascia on two garages were working from scaffold work platforms at greater than ten feet without the platform at least eighteen inches wide.  Employees were utilizing fourteen-inch wide aluminum stage planks supported on each end by a scaffold tower.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E06 I

Serious Gravity 10 4 instances 3 exposed
Issued
May 7, 2021
Abate by
Jun 14, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(e)(6)(i):  Integral prefabricated scaffold access frames shall be specifically designed and constructed for use as ladder rungs.  a)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, an employee was climbing on a top bar of a scaffold end frame eleven and one half feet above surface level to continue climbing down and over to the access/egress rungs.  Scaffold near the building's northwest corner did not have end frame rungs constructed for direct access/egress of the work platform.  b)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, an employee was climbing on the inside of end frames to access/egress a work platform twelve and one half feet above surface level.  Scaffold near the building's northwest corner did not have end frame rungs constructed for direct access/egress of the work platform.  c)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, an employee was climbing on a top bar of a scaffold end frame five and one half feet above surface level to continue climbing down access/egress rungs.  Scaffold near the building's northwest corner did not have end frame rungs constructed for direct access/egress of the work platform.  d)  On December 8,  2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, an employee was climbing on a top bar of a scaffold end frame greater than ten feet above surface level to continue climbing down and over to the access/egress rungs.  Scaffold near the building's northeast corner did not have end frame rungs constructed for direct access/egress of the work platform.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 3 instances 4 exposed
Issued
May 7, 2021
Abate by
Jun 14, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(1)(vii):  Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.  For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, employees were working from a scaffold platform at twelve and one half feet above surface level without utilizing conventional fall protection equipment on the gable end of the garage.  b)  On December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, employees were working from a scaffold work platform at eleven and one half feet above surface level without utilizing conventional fall protection equipment on the gable end of the garage.  c)  On or about December 8, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, employees were working from scaffold planks at greater than ten feet above surface level without utilizing conventional fall protection equipment on the long sides of the garage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A01

Serious Gravity 5 1 instance 6 exposed
Issued
May 7, 2021
Abate by
Jun 14, 2021
Penalty
Initial $2,926 · Current $2,048 Reduced
29 CFR  1926.454(a)(1):  The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the nature of any electrical hazards, fall hazards and falling object hazards in the work area;   On and about December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, the employer did not provide required scaffold use safety training for employees exposed to fall hazards greater than ten feet while installing metal siding, soffit, and fascia from scaffold platforms.
Recent events (2)
  • — I (S) $2048.2
  • — Z (S) $2926

1926.454 B02

Serious Gravity 5 1 instance 4 exposed
Issued
May 7, 2021
Abate by
Jun 14, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.454(b)(2):  The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. The training shall include the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question.  On and about December 10, 2020 at 9369 Thoroughfare Road in Minocqua, Wisconsin, the employer did not provide required scaffold assembly/disassembly safety training for employees erecting fabricated frame scaffold using seven-foot and twenty-foot long planks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Wickman Construction and Real Estate of Wisconsin LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345064794.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.