BATON ROUGE, LA ·
OSHA Inspection: STUCCO DESIGN LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STUCCO DESIGN LLC in 14149 BELLACOSA AVE, BATON ROUGE, LA 70816 (NAICS 238140). OSHA activity number 345071567.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STUCCO DESIGN LLC
- Site address
- 14149 BELLACOSA AVE
- City
- BATON ROUGE
- State
- LA
- ZIP
- 70816
- Mailing
- 3465 CEDARCREST AVENUE, BATON ROUGE, LA 70816
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.451 B01 II
- Issued
- Jan 26, 2021
- Abate by
- Feb 12, 2021
- Penalty
- Initial $2,926 · Current $2,926
General-duty citation text
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a)On or about December 17, 2020, on the north face of the building, employees were working on scaffolding at a height of twenty feet applying stucco to a new construction multilevel home without the scaffolding having a fully planked working surface across the uprights.
Recent events (1)
- · Z (S) $2926
1926.451 F14
- Issued
- Jan 26, 2021
- Abate by
- Feb 12, 2021
- Penalty
- Initial $2,926 · Current $2,926
General-duty citation text
29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: a) On or about December 17, 2020, on the north face of the building, employees were standing on a 2x6 plank between scaffolding levels at a height of approximately 17 feet while attempting to reach a higher work area to apply stucco.
Recent events (1)
- · Z (S) $2926
1926.451 C02
- Issued
- Jan 26, 2021
- Abate by
- Feb 12, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a)On or about December 17, 2020, on the north face of the building, employees were working on scaffolding at a height of twenty feet applying stucco to a new construction multilevel home that did not have installed mud sills.
Recent events (1)
- · Z (S) $4096
1926.451 E01
- Issued
- Jan 26, 2021
- Abate by
- Feb 12, 2021
- Penalty
- Initial $2,926 · Current $2,926
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about December 17, 2020, on the north face of the building employees were observed applying stucco while utilizing tube type scaffolding , that did not have a proper means of accessing or egressing.
Recent events (1)
- · Z (S) $2926
1926.501 B13
- Issued
- Jan 26, 2021
- Abate by
- Feb 12, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a)On or about December 17, 2020, on the north face of the building, employees were working on scaffolding at a height of twenty feet applying stucco to a new construction multilevel home without the use of fall protection systems.
Recent events (1)
- · Z (S) $4096
More inspections at Stucco Design LLC
View Stucco Design LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345071567.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.