Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALBINO CABRERA ESCOBAR

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALBINO CABRERA ESCOBAR in CLEAR VIEW HIGH SCHOOL REBUILD SITE 400 SOUTH WALNUT, WEBSTER, TX 77598 (NAICS 238160). OSHA activity number 345078109.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Albino Cabrera Escobar — free Get an email when a new federal OSHA severe-injury report for Albino Cabrera Escobar is published. One employer, no account, unsubscribe in one click.
Site address
CLEAR VIEW HIGH SCHOOL REBUILD SITE 400 SOUTH WALNUT
City
WEBSTER
State
TX
ZIP
77598
Mailing
12635 ZAVALLA STREET, HOUSTON, TX 77085
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
13
Ownership type
A

6 citations on file for this inspection.

1926.501 B14

Serious Gravity 5 1 instance 12 exposed
Issued
Feb 12, 2021
Abate by
Mar 18, 2021
Penalty
Initial $3,901 · Current $2,341 Reduced
29 CFR  1926.501(b)(14):Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system.  a)  On or about December 21, 2020, on the south end of the building, employees were engaged in roofing activities working near wall openings with an outside bottom edge more than 6 feet above a lower level without a fall protection system in place.
Recent events (2)
  • — I (S) $2340.6
  • — Z (S) $3901

1926.503 A02 II

Serious Gravity 5 1 instance 12 exposed
Issued
Feb 12, 2021
Abate by
Apr 2, 2021
Penalty
Initial $3,901 · Current $0 Reduced
29 CFR  1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:  a) On or about December 21, 2020, on the south end of the building, employees engaged in roofing activities  were not trained by a competent person in the correct procedures for erecting and maintaining the horizontal lifeline and warning line systems used to protect employees from fall hazards more than 6 feet above a lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3901

1926.502 F01 I

Serious Gravity 5 1 instance 12 exposed
Issued
Feb 12, 2021
Abate by
Mar 18, 2021
Penalty
Initial $3,901 · Current $2,341 Reduced
29 CFR  1926.502(f)(1)(i):  When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge:  a)  On or about December 21, 2020, on the south end of the building, a warning line intended to protect employees engaged in roofing activities on a low slope roof with unprotected sides and edges more than 6 feet above a lower level was not erected at least 6 feet from the roof edge.
Recent events (2)
  • — I (S) $2340.6
  • — Z (S) $3901

1926.502 F02 II

Serious Gravity 5 1 instance 12 exposed
Issued
Feb 12, 2021
Abate by
Mar 18, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.502(f)(2)(ii):The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface.  a)  On or about December 21, 2020, on the south end of the building, a warning line intended to protect employees engaged in roofing activities on a low slope roof with unprotected sides and edges more than 6 feet above a lower level was not rigged or supported to be at least 34 and no more than 39 inches from the walking/working surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D08

Serious Gravity 5 1 instance 12 exposed
Issued
Feb 12, 2021
Abate by
Mar 18, 2021
Penalty
Initial $3,901 · Current $0 Reduced
29 CFR  1926.502(d)(8):Horizontal lifelines were not designed, installed, and used under the supervision of a qualified person, as part of a complete personal fall arrest system, which maintained a safety factor of at least two:  a)  On or about December 21, 2020, on the south end of the building, employees engaged in roofing activities on a low slope roof with unprotected sides and edges more than 6 feet above a lower level used a horizontal lifeline not designed, installed and used under supervision of a qualified person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3901

1926.501 B10

Repeat Gravity 5 1 instance 12 exposed
Issued
Feb 12, 2021
Abate by
Mar 18, 2021
Penalty
Initial $7,802 · Current $4,681 Reduced
29 CFR  1926.501(b)(10):  Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.  a) On or about December 21, 2020, on the south end of the building, employees engaged in roofing activities on a low slope roof with unprotected sides and edges more than 6 feet above a lower level without a fall protection system in place.   Albino Cabrera Escobar, dba AC Roofing System was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1424855, citation number 01, item number 001 and was affirmed as a final order on November 20, 2019, with respect to a workplace located at 6631 Greenwoods Orchard Drive, Katy, TX 77449.
Recent events (2)
  • — I (R) $4681.2
  • — Z (R) $7802

View Albino Cabrera Escobar's full OSHA safety record →