WESTMONT, IL —
OSHA Inspection: MID-STATES CONCRETE INDUSTRIES, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MID-STATES CONCRETE INDUSTRIES, LLC in 1 WEST QUINCY STREET, WESTMONT, IL 60559 (NAICS 238120). OSHA activity number 345080758.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MID-STATES CONCRETE INDUSTRIES, LLC
- Site address
- 1 WEST QUINCY STREET
- City
- WESTMONT
- State
- IL
- ZIP
- 60559
- Mailing
- 500 SOUTH PARK AVENUE, SOUTH BELOIT, IL 61080
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 235
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.21 B02
- Issued
- Apr 16, 2021
- Abate by
- Jun 7, 2021
- Penalty
- Initial $12,288 · Current $5,000 Reduced
General-duty citation text
29 CFR 1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: On or about December 28, 2020 at the above jobsite address, employees were not adequately trained on the hazards associated with erection of precast concrete. Employees were exposed to struck-by and crushing hazards when the employer failed to train them on means and methods for properly supporting structural members to prevent collapse. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $5000
- — Z (S) $12288
1926.704 A
- Issued
- Apr 16, 2021
- Abate by
- May 14, 2021
- Penalty
- Initial $12,288 · Current $12,000 Reduced
General-duty citation text
29 CFR 1926.704(a):Precast concrete wall units, structural framing and tilt-up wall panels were not adequately supported to prevent overturning and to prevent collapse until permanent connections were completed: On or about December 28, 2020 at the above addressed jobsite, employees installing precast planking on the second story of a commercial jobsite were exposed to struck-by and crushing hazards due to a support beam not being adequately supported to prevent overturning and collapse. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $12000
- — Z (S) $12288
More inspections at Mid-States Concrete Industries, LLC
View Mid-States Concrete Industries, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345080758.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.