Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATLANTIC HEALTH SYSTEM

Federal Agency inspection · Health discipline

On , OSHA opened a federal Agency health inspection of ATLANTIC HEALTH SYSTEM in 97 WEST PARKWAY, POMPTON PLAINS, NJ 07444 (NAICS 622110). OSHA activity number 345082952.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic Health System — free Get an email when a new federal OSHA severe-injury report for Atlantic Health System is published. One employer, no account, unsubscribe in one click.
Site address
97 WEST PARKWAY
City
POMPTON PLAINS
State
NJ
ZIP
07444
Mailing
97 WEST PARKWAY, POMPTON PLAINS, NJ 07444
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
1412
Ownership type
A

4 citations on file for this inspection.

1910.134 D01 II

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Jul 27, 2021
Abate by
Aug 18, 2021
Penalty
Initial $13,653 · Current $13,653

Hazardous substances 8400

29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification:  a) IMCU, Atlantic Health System dba Chilton Medical Center, 97 West Parkway, Pompton Plains, NJ 07444.  The employer did not provide NIOSH-certified respirators to IMCU employees including, but not limited to Registered Nurses required to care for suspected and confirmed positive COVID-19 patients. The employer provided and required employees to wear respirators labeled KN95. The respirators were not NIOSH-certified.  Violation occurred on or about 2/18/2021 and thereafter.
Recent events (2)
  • — I (O) $13653
  • — Z (S) $13653

1910.134 F02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jul 27, 2021
Abate by
Aug 18, 2021
Penalty
Initial $0 · Current $0

Hazardous substances 8400

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator or annually refitted:  a) ICU, Atlantic Health System dba Chilton Medical Center, 97 West Parkway, Pompton Plains, NJ 07444.  The employer did not provide an annual fit test to all employees required to wear N-95 respirators. The employer provided and required employees including, but not limited to ICU Registered Nurses to wear N95 respirators to protect against the SARS-CoV-2 virus while providing care to suspected and confirmed positive COVID-19 patients.    Violation occurred on or about 2/18/2021 and thereafter.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1904.4 A

Other-than-serious 1 instance 3 exposed
Issued
Jul 27, 2021
Penalty
Initial $1,951 · Current $1,000 Reduced
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent:  Atlantic Health System dba Chilton Medical Center, 97 West Parkway, Pompton Plains, NJ 07444.  The employer did not record cases with days away from work for employees diagnosed with COVID-19 related illness and lost work time on the OSHA 300 Log for calendar year 2021 to include but not limited to:  a) On or about 01/28/2021 the employer failed to record the COVID-19 positive illness of a Registered Nurse who was out of work due to COVID-19 on 1/22/2021.  b) On or about 03/26/2021 the employer failed to record the COVID-19 positive illness of a Secretary/Nursing Assistant who was out of work due to COVID-19 on 03/20/2021.  c) On or about 04/02/2021 the employer failed to record the COVID-19 positive illness of a Patient Care Technician who was out of work due to COVID-19 on 03/26/2021.   Violation occurred on or about 1/28/2021, and thereafter.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1951

1910.134 M02 I C

Other-than-serious 1 instance 9 exposed
Issued
Jul 27, 2021
Abate by
Aug 18, 2021
Penalty
Initial $1,095 · Current $0 Reduced

Hazardous substances 8400

29 CFR 1910.134(m)(2)(i)(C): The employer did not establish a record of the qualitative and quantitative fit tests administered to an employee which included the specific make, model, style and size of respirator tested:  a) ICU and IMCU, Atlantic Health System dba Chilton Medical Center, 97 West Parkway, Pompton Plains, NJ 07444.  The employer provided and required employees including, but not limited to Registered Nurses to wear N-95 respirators. Employee fit testing records did not include the model and/or size of N-95 respirator.  Violation occurred on or about 2/18/2021 and thereafter.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1095

View Atlantic Health System's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345082952.