Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SANDRA J. SILVA DBA ROJAS TUCKPOINTING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SANDRA J. SILVA DBA ROJAS TUCKPOINTING, INC. in 2300 EMERSON, EVANSTON, IL 60201 (NAICS 238140). OSHA activity number 345090302.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sandra J. Silva DBA Rojas Tuckpointing, INC. — free Get an email when a new federal OSHA severe-injury report for Sandra J. Silva DBA Rojas Tuckpointing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2300 EMERSON
City
EVANSTON
State
IL
ZIP
60201
Mailing
1819 HOVLAND CT., EVANSTON, IL 60201
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2021
Abate by
Feb 5, 2021
Penalty
Initial $2,341 · Current $1,500 Reduced
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:      a) On or about January 5, 2021, employees were exposed to the hazard of falling from a frame scaffold that was not equipped with safe access.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2341

1926.451 G01

Serious Gravity 10 2 instances 2 exposed
Issued
Feb 1, 2021
Abate by
Feb 5, 2021
Penalty
Initial $4,096 · Current $2,500 Reduced
29 CFR  1926.451(g)(1):Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers:  a) On or about January 5, 2021, employees were exposed to the hazard of falling approximately 19 feet while working from frame scaffolding without the benefit of fall protection.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4096

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 1, 2021
Abate by
Feb 5, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):       a) On or about January 5, 2021, employees were exposed to the hazard of falling approximately 19 feet while performing masonry work from a pitched roof surface without fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.