ARABI, LA —
OSHA Inspection: ARMANDO PAZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARMANDO PAZ in 404 SERPAS DR., ARABI, LA 70032 (NAICS 238140). OSHA activity number 345091250.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMANDO PAZ
- Site address
- 404 SERPAS DR.
- City
- ARABI
- State
- LA
- ZIP
- 70032
- Mailing
- 310 MANSON AVE., METAIRIE, LA 70001
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01 I
- Issued
- Feb 25, 2021
- Abate by
- Mar 3, 2021
- Penalty
- Initial $1,755 · Current $1,755
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a) On or about January 7, 2021, at the front of the residence, while working from a scaffold not fully planked, an employee was applying stucco to the exterior of a building approximately 8 feet above the ground.
Recent events (1)
- — Z (S) $1755
1926.451 C02
- Issued
- Feb 25, 2021
- Abate by
- Mar 3, 2021
- Penalty
- Initial $1,755 · Current $1,755
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) On or about January 6, 2021, at the front of the residence, an employee was applying stucco to the exterior of a building from a scaffold that did not have mud sills or an adequate firm foundation.
Recent events (1)
- — Z (S) $1755
1926.451 E01
- Issued
- Feb 25, 2021
- Abate by
- Mar 3, 2021
- Penalty
- Initial $1,755 · Current $1,755
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about January 6, 2021, at the front of the residence, the employer allowed employees to access and egress a scaffold while not having a ladder attached.
Recent events (1)
- — Z (S) $1755