APPLETON, WI —
OSHA Inspection: SCOTT DENOBLE AND SONS CONSTRUCTION, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCOTT DENOBLE AND SONS CONSTRUCTION, INC in INNOVATION CT. AND TRI-PARK WAY, APPLETON, WI 54914 (NAICS 237110). OSHA activity number 345093082.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCOTT DENOBLE AND SONS CONSTRUCTION, INC
- Site address
- INNOVATION CT. AND TRI-PARK WAY
- City
- APPLETON
- State
- WI
- ZIP
- 54914
- Mailing
- 1910 VERLIN RD., GREEN BAY, WI 54311
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.652 D02
- Issued
- Apr 1, 2021
- Penalty
- Initial $2,633 · Current $1,843 Reduced
General-duty citation text
29 CFR 1926.652(d)(2): Manufactured materials and equipment used for protective systems shall be used and maintained in a manner that is consistent with the recommendations of the manufacturer, and in a manner that will prevent employee exposure to hazards: At a worksite located at the southwest corner of Tri-Park Way and Innovation Court in Appleton, Wisconsin, the employer did not use protective systems in a manner that was consistent with the recommendations of the manufacturer, and in a manner that will prevent employee exposure to hazards: a) The Pro-Tec Trench Shield (Model PRO4-816D, S# 16549) was stacked on a different manufacturer's trench shield (Efficiency Production Inc. Model MHXLDF-810, S# 127737) without the use of manufacturer approved stack connections as specified in the PRO4-816D's "Trench Shield Certification" (tabulated data sheet). This instance exposed employees to potential lateral movement of the stacked trench shield. b) The Pro-Tech Trench Shield (Model PRO4-816D, S#16549) was installed without adequate cave-in protection while employees conduced tie-in of storm/sewage water components in an approximately 14-feet deep excavation. A steel road plate and half-inch plywood sheet were placed along the northern, open end of the trench shield. This instance exposed employees to potential cave-in hazards. c) The Efficiency Production Inc. Trench Shield (Model MHXLDF-810, S# 127737), which was used for tying-in storm/sewage water components in an approximately 14 feet deep excavation, was not installed with manufacturer designed end plates to protect from cave-ins. A steel road plate was placed along the northern, open end of the trench shield, and two smaller steel road plates were placed along the southern open end of the trench shield. This instance exposed employees to potential cave-in hazards.
Recent events (2)
- — I (S) $1843.1
- — Z (S) $2633
More inspections at Scott Denoble and Sons Construction, INC
View Scott Denoble and Sons Construction, INC's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345093082.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.