Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KEYSTONE MASONRY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEYSTONE MASONRY, LLC in 1704 SPOKE STREET, OKLAHOMA CITY, OK 73109 (NAICS 238140). OSHA activity number 345099303.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keystone Masonry, LLC — free Get an email when a new federal OSHA severe-injury report for Keystone Masonry, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1704 SPOKE STREET
City
OKLAHOMA CITY
State
OK
ZIP
73109
Mailing
7116 NW 21ST ST., BETHANY, OK 73008
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 2, 2021
Penalty
Initial $2,341 · Current $1,200 Reduced
29 CFR  1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  On or about January 13, 2021, at the west side of the building, the supported scaffold platform was more than 2 feet above the ground and a safe means to access the scaffold was not provided.  Employees doing brick work at the 3rd scaffold platform were exposed to falls when accessing scaffold platforms.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2341

1926.451 G01 VI

Serious Gravity 5 2 instances 6 exposed
Issued
Apr 2, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(1)(vi):  Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).   On or about January 13, 2021, at the building exterior, the following areas of the supported scaffold lacked guardrails and was greater than 10 feet from the ground:  a.	West end of the supported scaffold, 3rd tier, and b.	Middle of the supported scaffold, 3rd tier.  Employees performing overhand bricklaying work at the 3rd tier of the supported scaffold, were exposed to falls greater than 10 feet to a lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Keystone Masonry, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345099303.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.