Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOUNT SAINT CHARLES ACADEMY, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MOUNT SAINT CHARLES ACADEMY, INC. in 800 LOGEE ST, WOONSOCKET, RI 02895 (NAICS 611110). OSHA activity number 345107254.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mount Saint Charles Academy, INC. — free Get an email when a new federal OSHA severe-injury report for Mount Saint Charles Academy, INC. is published. One employer, no account, unsubscribe in one click.
Site address
800 LOGEE ST
City
WOONSOCKET
State
RI
ZIP
02895
Mailing
800 LOGEE ST, WOONSOCKET, RI 02895
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
611110
Employees
122
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2021
Penalty
Initial $8,778 · Current $5,800 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were not protected from crushing, struck-by, pinched or caught-in and fall type hazards while using a freight elevator:  (a) Freight elevator and stairwell located in the food service receiving area:  On or about 1/8/2021, employees were exposed to crushing, struck-by, pinched or caught-in and fall type hazards while using the freight elevator that services the school kitchen, where trash is removed from the kitchen area to the upper level.
Recent events (2)
  • — I (S) $5800
  • — Z (S) $8778

1910.25 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2021
Abate by
Sep 7, 2021
Penalty
Initial $8,778 · Current $5,800 Reduced
29 CFR 1910.25(b)(3): The employer did not ensure that stairs have uniform riser heights and tread depths between landings:  (a) Stairwell adjacent to the service freight elevator serving the school kitchen:  On or about 1/8/21, the employer did not ensure that the stairs have uniform riser heights and tread depths exposing employees to fall hazards from slips and trips while using the stairs to access the freight elevator and outside trash dumpsters.
Recent events (2)
  • — I (S) $5800
  • — Z (S) $8778

1910.25 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2021
Abate by
Sep 7, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.25(b)(5)(i): The employer did not ensure that when a door or a gate opens directly on a stairway, a platform is provided, and the swing of the door or gate does not reduce the platform's effective usable depth to less than 20 inches (51 cm) for platforms installed before January 17, 2017:  (a) Stairwell adjacent to the service freight elevator serving the school kitchen:  On or about 1/8/21, the employer did not ensure that when the door at the midpoint of the stairwell was opened, a platform of at least 20 inches was available.  The platform was entirely blocked by the opening door, exposing employees to fall hazards from slips and trips while using the stairs to access the freight elevator and outside trash dumpsters.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.25 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2021
Abate by
Sep 7, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.25(c)(3): The employer did not ensure that standard stairs have a minimum tread depth of 9.5 inches (24 cm):  (a) Stairwell adjacent to the service freight elevator serving the school kitchen:  On or about 1/8/21, the employer did not ensure that the stairs had a minimum tread depth of 9.5 inches.  Tread depths of between 8.5 and 9 inches exposed employees to fall hazards from slips and trips while using the stairs to access the freight elevator and outside trash dumpsters.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2021
Abate by
Sep 7, 2021
Penalty
Initial $8,778 · Current $5,800 Reduced
29 CFR 1910.29(b)(1): The employer did not ensure that guardrail systems met the requirement that the top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D11 of this section):  (a) Stairwell adjacent to the service freight elevator serving the school kitchen:  On or about 1/8/21, the employer did not ensure that guardrail systems had top rails that were no higher than 42 inches (plus or minus 3 inches) above the stair treads exposing employees to fall hazards of up to 14 feet while using the stairs to access the freight elevator and outside trash dumpsters:  1) The upper stairwell top rails were 48 inches above the stair treads, 2) The lower stairwell top rails were 33 inches above the stair treads.
Recent events (2)
  • — I (S) $5800
  • — Z (S) $8778

1910.29 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2021
Abate by
Sep 7, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2): The employer did not ensure that guardrail systems met the requirement that mid-rails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members that are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high:  (a) Stairwell adjacent to the service freight elevator serving the school kitchen:  On or about 1/8/21, the employer did not ensure that guardrail systems were provided with an adequate mid-rail exposing employees to fall hazards of up to 14 feet while using the stairs to access the freight elevator and outside trash dumpsters:  1) The upper stairwell was missing a mid rail for half of its length. 2) The lower stairwell had no mid-rail.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B05

Other-than-serious 1 instance 2 exposed
Issued
Jul 1, 2021
Abate by
Sep 7, 2021
Penalty
Initial $986 · Current $600 Reduced
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  (a) Doorway from kitchen into the freight elevator stairwell:  On or about 1/8/21, the door from the kitchen into the freight elevator stairwell was not labeled as either "not an exit" or with its actual use and could be mistaken for an exit, exposing employees to delays in exiting during an emergency.
Recent events (2)
  • — I (O) $600
  • — Z (O) $986

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345107254.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.