Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHLUMBERGER TECHNOLOGY CORPORATION

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SCHLUMBERGER TECHNOLOGY CORPORATION in 170 GILLINGHAM DRIVE, SUGAR LAND, TX 77478 (NAICS 213112). OSHA activity number 345113633.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schlumberger Technology Corporation — free Get an email when a new federal OSHA severe-injury report for Schlumberger Technology Corporation is published. One employer, no account, unsubscribe in one click.
Site address
170 GILLINGHAM DRIVE
City
SUGAR LAND
State
TX
ZIP
77478
Mailing
300 SCHLUMBERGER DRIVE, SUGAR LAND, TX 77478
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
105000
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 2 instances 6 exposed
Issued
Jul 13, 2021
Abate by
Aug 16, 2021
Penalty
Initial $13,653 · Current $8,191 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a)  In the facility workshop, on or about January 21, 2021 and at times prior thereto, the procedures to control potentially hazardous energy when Maintenance Technicians (MTs) and Maintenance Assemblers (MAs) connected and disconnected Maxwell MXW4 and MXW6 drill tools to the drill collar roll machines (DCRMs) were not utilized, exposing employees to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $8191
  • — Z (S) $13653

1910.147 D04 I

Serious Gravity 10 2 instances 6 exposed
Issued
Jul 13, 2021
Abate by
Aug 16, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   a)  In the facility workshop, on or about January 21, 2021 and at times prior thereto, lockout devices were  not affixed to each energy isolating device on the drill collar roll machines (DCRMs) by authorized employees when Maintenance Technicians (MTs) and Maintenance Assemblers (MAs) connected and disconnected Maxwell MXW4 and MXW6 drill tools, exposing employees to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 13, 2021
Abate by
Aug 16, 2021
Penalty
Initial $13,653 · Current $10,240 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts:   a)  In the facility workshop, the rotating drill tool attached to a drill collar roll machine (DCRM) was not guarded, exposing Electrical Technicians (ETs) to struck-by and caught-in hazards.
Recent events (2)
  • — I (S) $10240
  • — Z (S) $13653

View Schlumberger Technology Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345113633.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.