Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: R S A LED LIGHTING, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of R S A LED LIGHTING, INC in 100 HERRICKS ROAD, MINEOLA, NY 11501 (NAICS 238210). OSHA activity number 345115109.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R S a LED Lighting, INC for free Get an email when a new federal OSHA severe-injury report for R S a LED Lighting, INC is published. One employer, no account, unsubscribe in one click.
Site address
100 HERRICKS ROAD
City
MINEOLA
State
NY
ZIP
11501
Mailing
1619 HONE AVE 1ST FLOOR, BRONX, NY 10461
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1926.651 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 3, 2021
Penalty
Initial $2,926 · Current $2,926
29 CFR  1926.651(b)(1):The estimated location of underground utility installations, such as sewer, telephone, fuel, electric, water lines, or any other underground installations that reasonably may be expected to be encountered during excavation work, were not determined prior to opening an excavation.  a) Worksite, parking lot, westside of commercial structure:  On or about August 17, 2020, employees were exposed to electric shock hazards from underground high voltage power lines while digging to locate an underground electrical components.  Permits were not obtained in advance to mark underground utilities installations.  Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
  • · Z (S) $2926

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 3, 2021
Penalty
Initial $2,926 · Current $2,926
29 CFR  1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees.  a) Worksite, parking lot, westside of commercial structure:  On or about August 17, 2020, employees were exposed to delayed egress hazards while digging a hole to locate an underground electrical components.  A stairway, ladder, ramp, or safe means of egress was not located inside of the trench while employees were digging.  Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
  • · Z (S) $2926

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345115109.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.