Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAFESIDE CHIMNEY & DUCT CLEANING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAFESIDE CHIMNEY & DUCT CLEANING in 203 CEDAR RIDGE DRIVE, GLASTONBURY, CT 06033 (NAICS 561790). OSHA activity number 345115729.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Safeside Chimney & Duct Cleaning — free Get an email when a new federal OSHA severe-injury report for Safeside Chimney & Duct Cleaning is published. One employer, no account, unsubscribe in one click.
Site address
203 CEDAR RIDGE DRIVE
City
GLASTONBURY
State
CT
ZIP
06033
Mailing
120 LEDYARD STREET, HARTFORD, CT 06114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.451 C01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 6, 2021
Abate by
Aug 20, 2021
Penalty
Initial $3,901 · Current $2,731 Reduced
29 CFR  1926.451(c)(1)(iii):Ties, guys, braces, or outriggers were not installed to prevent the tipping of supported scaffolds in all circumstances where an eccentric load, such as a cantilevered work platform, was applied or was transmitted to the scaffold.  A) On or about January 14, 2021 at the 204 Cedar Ridge Drive, Glastonbury, CT job site:  The employer used a scaffold pulley wheel to transfer bricks and masonry supplies, including bags of sand and cement,  to the roof edge, approximately 8 feet from the ground level.  The scaffold was not secured to prevent tipping when the load was added.
Recent events (2)
  • — I (S) $2730.7
  • — Z (S) $3901

1926.451 C02

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 6, 2021
Abate by
Aug 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  A) On or about January 14, 2021 at the 204 Cider Ridge Drive, Glastonbury, CT job site:  The supported scaffold used by employees did not use a base plate, mud sill, or other adequate firm foundation to support the scaffold poles.  The poles were set on the bare ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 6, 2021
Abate by
Aug 20, 2021
Penalty
Initial $3,901 · Current $2,731 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    A) On or about January 14, 2021 at the 204 Cedar Ridge Drive, Glastonbury, CT job site:  Two employees working on the chimney of the house were not protected from falls from elevation, when accessing the pitched roof from the supported scaffold.  Employees were exposed to falls of 8 feet to the ground below.
Recent events (2)
  • — I (S) $2730.7
  • — Z (S) $3901

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345115729.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.