Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,547Inspections Most recent open 2026-09-01 Last loaded 2026-09-04

OSHA Inspection: STR FAB, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STR FAB, LLC in 1616 DUVALL RD, CHATSWORTH, GA 30705 (NAICS 332312). OSHA activity number 345119556.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch STR FAB, LLC for free Get an email when a new federal OSHA severe-injury report for STR FAB, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
STR FAB, LLC
Site address
1616 DUVALL RD
City
CHATSWORTH
State
GA
ZIP
30705
Mailing
1616 DUVALL RD, CHATSWORTH, GA 30705
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
57
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 8, 2021
Penalty
Initial $4,642 · Current $2,785 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  a) Production Area, Black Slitter Machine: On or about January 27, 2021, and at times prior, an employee was exposed to struck-by and caught-in hazards, in that the energy control procedures for the Cut Table Slitter # 2 (Black Slitter Table) did not clearly and specifically outline the steps for shutting down and isolating hazardous mechanical energy.
Recent events (2)
  • · I (S) $2785.2
  • · Z (S) $4642

1910.304 F01 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 8, 2021
Penalty
Initial $4,642 · Current $2,785 Reduced
29 CFR  1910.304(f)(1)(v): The employer did not ensure that fuses and circuit breakers were so located or shielded that employees will not be burned or otherwise injured by their operation.    a) Production Area, Black Slitter Machine: On or about January 27, 2021, and at times prior, an employee tasked with servicing the Cut Table Slitter # 2 (Black Slitter Table) was not protected from electrical burns, in that the employee was in close proximity to unshielded fuses and circuit breakers when disconnecting the hazardous energy source (electricity) .
Recent events (2)
  • · I (S) $2785.2
  • · Z (S) $4642

1910.22 A03

Other-than-serious 1 instance 1 exposed
Issued
Jul 8, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.   a) Production Area, Slitter Machine Number Two: On or about January 27, 2021, and at times prior, an employee was exposed to trip and fall hazards, in that a 1/2 inch metal electrical conduit installed on the floor was not properly covered.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345119556.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.