Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACC MASTERCRAFT ROOFING CONTRACTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACC MASTERCRAFT ROOFING CONTRACTORS, INC. in 2885 LAKE RIDGE LANE, WESTON, FL 33326 (NAICS 238160). OSHA activity number 345123210.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACC Mastercraft Roofing Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for ACC Mastercraft Roofing Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2885 LAKE RIDGE LANE
City
WESTON
State
FL
ZIP
33326
Mailing
3350 NW 22 TERR., SUITE 900-1100, POMPANO BEACH, FL 33069
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2021
Penalty
Initial $2,926 · Current $1,756 Reduced
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   On or about 01/29/2021, at 2885 Lake Ridge Lane, Weston, Florida, employees working on the roof of a two story residential home without fall protection were exposed to a fall hazard of approximately 20-feet to the ground.
Recent events (2)
  • — I (S) $1755.6
  • — Z (S) $2926

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 29, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:  On or about 01/29/2021, at 2885 Lake Ridge Lane, Weston, Florida, employees were using a portable ladder to access the upper roof of a residence and the ladder did not extend at least 3-feet above the edge of the roof exposing the employees to a fall hazard of approximately 10-feet to a lower roof.
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

View ACC Mastercraft Roofing Contractors, INC.'s full OSHA safety record →