WESTON, FL —
OSHA Inspection: ACC MASTERCRAFT ROOFING CONTRACTORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACC MASTERCRAFT ROOFING CONTRACTORS, INC. in 2885 LAKE RIDGE LANE, WESTON, FL 33326 (NAICS 238160). OSHA activity number 345123210.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACC MASTERCRAFT ROOFING CONTRACTORS, INC.
- Site address
- 2885 LAKE RIDGE LANE
- City
- WESTON
- State
- FL
- ZIP
- 33326
- Mailing
- 3350 NW 22 TERR., SUITE 900-1100, POMPANO BEACH, FL 33069
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 29, 2021
- Penalty
- Initial $2,926 · Current $1,756 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about 01/29/2021, at 2885 Lake Ridge Lane, Weston, Florida, employees working on the roof of a two story residential home without fall protection were exposed to a fall hazard of approximately 20-feet to the ground.
Recent events (2)
- — I (S) $1755.6
- — Z (S) $2926
1926.1053 B01
- Issued
- Jan 29, 2021
- Penalty
- Initial $2,341 · Current $1,405 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: On or about 01/29/2021, at 2885 Lake Ridge Lane, Weston, Florida, employees were using a portable ladder to access the upper roof of a residence and the ladder did not extend at least 3-feet above the edge of the roof exposing the employees to a fall hazard of approximately 10-feet to a lower roof.
Recent events (2)
- — I (S) $1404.6
- — Z (S) $2341
More inspections at ACC Mastercraft Roofing Contractors, INC.
View ACC Mastercraft Roofing Contractors, INC.'s full OSHA safety record →