YONKERS, NY —
OSHA Inspection: MCLEOD BROTHERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MCLEOD BROTHERS, INC. in 21 BRANDON ROAD, YONKERS, NY 10704 (NAICS 238170). OSHA activity number 345132013.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCLEOD BROTHERS, INC.
- Site address
- 21 BRANDON ROAD
- City
- YONKERS
- State
- NY
- ZIP
- 10704
- Mailing
- 30 CHURCH STREET, NEW ROCHELLE, NY 10801
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Jun 2, 2021
- Penalty
- Initial $3,862 · Current $2,294 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. A) Exterior, On the roof: Employees were exposed to eye/face injuries while using pneumatic nail guns and were not protected with any type of eye/face protection, on or about December16th, 2020. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $2294
- — Z (S) $3862
1926.451 G01
- Issued
- Jun 2, 2021
- Penalty
- Initial $4,505 · Current $2,676 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. A) Exterior, Pump jack scaffold on the left side of the structure: An employee was exposed to fall hazards of approximately 22 feet while working on a pump jack scaffold that was not protected by a complete guardrail system (including end rails) or another means of fall protection in place, on or about December 16th, 2020. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $2676
- — Z (S) $4505
1926.1051 A
- Issued
- Jun 2, 2021
- Penalty
- Initial $4,505 · Current $2,676 Reduced
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. A) Exterior, On the scaffold: An employee was exposed to fall hazards of approximately 22 as he was climbing down over the ladder jack scaffold instead of using a separate ladder on or about December 16th, 2020. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (S) $2676
- — Z (S) $4505
1926.501 B13
- Issued
- Jun 2, 2021
- Penalty
- Initial $9,011 · Current $5,354 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): A) Upper Roof of the structure: Employees were exposed to fall hazards of approximately 25 feet while engaged in roofing work on the roof of a structure without a means of fall protection in place, on or about December 16th, 2020. B) Front Porch roof: Employees were exposed to fall hazards of approximately 12 & 25 feet while engaged in roofing work on the roof of a structure without a means of fall protection in place, on or about December 16th, 2020. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. Mcleod Brothers, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (CFR 19100028 B01 I, which was contained in OSHA inspection number 1419634, citation number 1, item number 1 and was affirmed as a final order on August 13th 2019, with respect to a workplace located at 325 Highbrook Avenue in Pelham, NY.
Recent events (2)
- — I (R) $5354
- — Z (R) $9011
More inspections at Mcleod Brothers, INC.
View Mcleod Brothers, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345132013.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.