Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALEJANDRO TORRES TORRES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALEJANDRO TORRES TORRES in 2816 CHESTER FIELD, MANSFIELD, TX 76063 (NAICS 238350). OSHA activity number 345132583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alejandro Torres Torres — free Get an email when a new federal OSHA severe-injury report for Alejandro Torres Torres is published. One employer, no account, unsubscribe in one click.
Site address
2816 CHESTER FIELD
City
MANSFIELD
State
TX
ZIP
76063
Mailing
2614 MARFA AVE., DALLAS, TX 75216
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.451 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 19, 2021
Penalty
Initial $1,990 · Current $1,194 Reduced
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide.  On the east side of the construction site, employees engaged in cornice work on a residential home from single pole scaffold, work from a platform not 18 inches wide.  The employees were expose to potential fall hazard of approximately 12 feet to the ground below.
Recent events (2)
  • — I (S) $1194
  • — Z (S) $1990

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 19, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  On the east side of the construction site, an employee work from a pole scaffold without fall protection systems while installing cornice material on the exterior of a residential home.  The employee was expose to a fall hazards of approximately 12 feet to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 A04

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 19, 2021
Penalty
Initial $1,492 · Current $895 Reduced
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds.  On the east side of the construction site, an employee working from a pole scaffold without cross bracing installed was expose to a fall hazard of approximately 12 feet to the ground below.
Recent events (2)
  • — I (S) $895.2
  • — Z (S) $1492

View Alejandro Torres Torres's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345132583.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.