OSHA Inspection: U.S. FOREST SERVICE, PAISLEY RANGER DISTRICT 8AGFS0441

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. FOREST SERVICE, PAISLEY RANGER DISTRICT 8AGFS0441 in HIGHWAY 31, PAISLEY, OR 97636 (NAICS 924120). OSHA activity number 345142632.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Forest Service, Paisley Ranger District 8agfs0441 — free Get an email when a new federal OSHA severe-injury report for U.S. Forest Service, Paisley Ranger District 8agfs0441 is published. One employer, no account, unsubscribe in one click.
Site address
HIGHWAY 31
City
PAISLEY
State
OR
ZIP
97636
Mailing
P.O. BOX 67, PAISLEY, OR 97636
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
300
Ownership type
D

3 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 30, 2021
Abate by
Jul 22, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(5):Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades were not guarded. The guard shall have openings no larger than one-half (1/2) inch.  (a) Automotive Shop - On or about February 10, 2021 and at times prior thereto, employees were exposed to the rotating blades of the heater/fan that was permanently installed adjacent to the workbench.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 30, 2021
Abate by
Jul 22, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(2)(i): Live�parts of�electric equipment�operating at�50 volts�or more�were not�guarded against�accidental contact by�use of�approved cabinets�or other�forms of�approved enclosures.  (a) Workcenter - On or about February 10, 2021 and at time prior thereto, employees were exposed to an electrical shock of 110VAC in that live parts of the outlet were not covered .
Recent events (1)
  • — Z (S) $0

1910.213 B03

Repeat Gravity 5 1 instance 1 exposed
Issued
Jun 30, 2021
Abate by
Jul 22, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.213(b)(3): On applications where injury to the operator might result if motors were to restart after power failures, provisions were not made to prevent machines from automatically restarting upon restoration of power.  (a) Workcenter - On or about February 10, 2021 and at times prior thereto, employees were exposed to the rotating blade on the DeWalt Radial Arm Saw in that there was no anti-restart device in the event of a power failure.  The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(b)(3) which was contained in OSHA inspection number 1261318, citation number  2, item number 2 and was affirmed as a final order on 3/20/2018 , with respect to a workplace located at the Hood River Ranger District's Parkdale Work Center.
Recent events (1)
  • — Z (R) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345142632.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.