Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SKYCOASTER OF FLORIDA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SKYCOASTER OF FLORIDA, LLC in 2850 FLORIDA PLAZA BLVD, KISSIMMEE, FL 34747 (NAICS 713110). OSHA activity number 345143184.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Skycoaster of Florida, LLC — free Get an email when a new federal OSHA severe-injury report for Skycoaster of Florida, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2850 FLORIDA PLAZA BLVD
City
KISSIMMEE
State
FL
ZIP
34747
Mailing
2850 FLORIDA PLAZA BLVD, KISSIMMEE, FL 34747
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713110
Employees
200
Ownership type
A

3 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 100 exposed
Issued
Apr 21, 2021
Abate by
May 10, 2021
Penalty
Initial $9,753 · Current $5,364 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. On or about February 10, 2021, at the bumper car ride, the AC power supply for the two car rides had the electrical boxes installed in such a way that they were exposed to getting wet during inclement weather conditions.  The 400 amp power supply boxes were not water proof and were installed by having a wooden box which was open on one side placed over them.  b. On or about February 10, 2021, at the bumper car ride operator station, an outdoor outlet box with two receptacles had a scanner and an extension strip plugged into it without having the cover sealing the box as designed. The box cover was cracked open allowing water to enter during inclement weather conditions.
Recent events (2)
  • — I (S) $5364.15
  • — Z (S) $9753

1910.303 G01 III

Other-than-serious 1 instance 9 exposed
Issued
Apr 21, 2021
Abate by
May 10, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(iii):The employer did not ensure that at least one entrance of sufficient area was provided to give access to the working space about electric equipment 600 Volts, nominal, or less.  a. On or about February 10, 2021, at the bumper car ride, maintenance employees were expose to the hazard of having to climb over metal railings to access the power supply boxes, in that, an access entrance was not provided to the location where the two power supply boxes were installed which was enclosed with metal railings.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 100 exposed
Issued
Apr 21, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a. On or about February 10, 2021, at the bumper car ride, employees were exposed to electrical hazards, in that, temporary wiring such as a one foot flexible extension cord was permanently installed and was used to provide power to the PA system.