FORT MYERS, FL —
OSHA Inspection: AFFORDABLE CUSTOM BUILDERS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AFFORDABLE CUSTOM BUILDERS, LLC in 4213 BLOOMFIELD STREET, FORT MYERS, FL 33916 (NAICS 238130). OSHA activity number 345144570.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AFFORDABLE CUSTOM BUILDERS, LLC
- Site address
- 4213 BLOOMFIELD STREET
- City
- FORT MYERS
- State
- FL
- ZIP
- 33916
- Mailing
- 13019 CARIBBEAN BLVD, FORT MYERS, FL 33905
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- May 5, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) While at the jobsite, employees were performing roof sheathing on a 5/12 slope and framing the roofing area of a residence without fall protection, exposing the employees to a fall hazard approximately 10' feet on or about 11 February 2021.
Recent events (1)
- — Z (S) $4096
1926.1053 B01
- Issued
- May 5, 2021
- Penalty
- Initial $2,341 · Current $2,341
General-duty citation text
29 CFR 1926.1053(b)(1):Where (a) portable ladder(s) was/were used for access to an upper level landing surface the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) On the south (front of home) east side, a 12' extension ladder was being utilized that was not long enough to extend 3 feet above the roof edge. The ladder extended approximately 1' over the edge, exposing the employees to a fall hazard on or about 11 February 2021.
Recent events (1)
- — Z (S) $2341
More inspections in this industry (NAICS 238130)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345144570.