Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WENGER TEMPERATURE CONTROL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WENGER TEMPERATURE CONTROL in 6261 ALBANY WAY, WESTERVILLE, OH 43081 (NAICS 238220). OSHA activity number 345146906.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wenger Temperature Control — free Get an email when a new federal OSHA severe-injury report for Wenger Temperature Control is published. One employer, no account, unsubscribe in one click.
Site address
6261 ALBANY WAY
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
2005 PROGRESS AVENUE, COLUMBUS, OH 43207
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
28
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 21, 2021
Abate by
Jul 16, 2021
Penalty
Initial $9,557 · Current $5,000 Reduced
29 CFR  1926.501(b)(11):"Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toe boards, safety net systems, or personal fall arrest systems.  a.  On or about February 12, 2021,  the employer did not ensure that an employee engaged in commercial construction activities six feet or more above lower level were protected from falls. An employee  was working on HVAC penetrations on a steep roof at heights of over 14 feet without adequate fall protection. The following condition exposed the employee to falls of over 14 feet.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9557

1926.502 D16 III

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 21, 2021
Abate by
Jul 16, 2021
Penalty
Initial $9,557 · Current $0 Reduced
29 CFR  1926.502(d)(16):Personal fall arrest systems, when stopping a fall, shall:  29 CFR  1926.502(d)(16)(iii): be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level;  a. On or about February 12, 2021, the employer did not ensure that an employee was adequately protected from falls while engaged in commercial construction activities. An employee working on HVAC penetrations on a steep roof at heights of over 14 feet with lifelines that were not adjusted to prevent a free fall to less than 6 feet, thereby exposing the employee to fall hazards of over 14 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9557

View Wenger Temperature Control's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345146906.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.