Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAFEWAY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SAFEWAY, INC. in 4301 FOREST STREET, DENVER, CO 80216 (NAICS 311511). OSHA activity number 345148852.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Safeway, INC. — free Get an email when a new federal OSHA severe-injury report for Safeway, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SAFEWAY, INC.
Site address
4301 FOREST STREET
City
DENVER
State
CO
ZIP
80216
Mailing
4301 FOREST STREET, DENVER, CO 80216
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311511
Employees
58
Ownership type
A

8 citations on file for this inspection.

1910.22 A03

Serious Gravity 5 2 instances 10 exposed
Issued
Aug 10, 2021
Abate by
Jun 28, 2022
Penalty
Initial $11,703 · Current $11,703
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.   a) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not ensure employees were protected from injury in the Blowmold Room-Building 8042 in that JEFFCOOL P200 and Clarity Hydraulic Oil used in the Blowmold Machines leaked onto walking-working surfaces.  Spill containment pads were not replaced when they became fully saturated.  This condition exposed employees to slip and trip hazards.    b) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not ensure employees were protected from injury in the Blowmold Room-Building 8042 in that JEFFCOOL P200 and Clarity Hydraulic Oil used in the Blowmold Machines leaked onto walking-working surfaces.  Loose cardboard pieces were placed on the floor along the base of the machines.  This condition exposed employees to slip and trip hazards.
Recent events (3)
  • — F (S) $11703
  • — C (S) $11703
  • — Z (S) $11703

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 10, 2021
Abate by
Jun 28, 2022
Penalty
Initial $13,653 · Current $13,653
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On February 12, 2021, the operator was making a roll adjustment on the Uniloy Milacron Model 350R5 Blowmold Machine #1, serial number 350R5-3149, when the machine automatically cycled and amputated all four of her fingers on one hand.  This condition exposed employees to caught-in-between, crushing, and amputation hazards.
Recent events (3)
  • — F (S) $13653
  • — C (S) $13653
  • — Z (S) $13653

1910.147 C05 I

Serious Gravity 10 9 instances 6 exposed
Issued
Aug 10, 2021
Abate by
Jun 28, 2022
Penalty
Initial $13,653 · Current $13,653
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:   a) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Boilers 1 and 2. b) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the 7-pattern palletizer. c) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on Half-gallon, quart, and gallon casers. d) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on Case washer. e) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Blowmold machines. f) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on Half-gallon, quart, and gallon stackers. g) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the HTST 1 and 2, Hot Water Set Pumps. h) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Cheese palletizer. i) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not provide authorized employees with a sufficient number of locks to properly isolate every energy source on multiple pieces of equipment. This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Raw tank agitator.
Recent events (3)
  • — F (S) $13653
  • — C (S) $13653
  • — Z (S) $13653

1910.147 C06 I

Serious Gravity 10 10 instances 8 exposed
Issued
Aug 10, 2021
Abate by
Jun 28, 2022
Penalty
Initial $13,653 · Current $13,653
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedures at least annually to ensure that the procedures and the requirement of this standard were being followed:   a) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on Boilers 1 and 2. b) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the 7-pattern palletizer. c) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Half-gallon, quart, and gallon casers. d) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Case washer. e) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Blowmold machines and Blowmold trimmers. f) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Half-gallon, quart, and gallon stackers. g) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on HTST 1 and 2, Hot water set pumps. h) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Blowmold grinders. i) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Cheese palletizer. j) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not conduct a periodic inspection with authorized employees within the past 12 months of the Lockout/Tagout (LOTO) procedures used by maintenance/authorized employees.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards when working on the Raw tank agitator.
Recent events (3)
  • — F (S) $13653
  • — C (S) $13653
  • — Z (S) $13653

1910.147 C07 I

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 10, 2021
Abate by
Jun 28, 2022
Penalty
Initial $13,653 · Current $13,653
29 CFR  1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) Safeway Inc., at 4301 Forest Street, Denver CO 80216:  On or before February 16, 2021, the employer did not provide adequate training to ensure that employees acquired the knowledge and skills necessary for the safe application, usage and removal of energy control devices including, but not limited to the following machines or equipment:    	Boilers 1 and 2 	7-pattern palletizer 	Half-gallon, quart, and gallon casers 	Case washer 	Blowmold machines and blowmold trimmers 	Half-gallon, quart, and gallon stackers  	Pasteurizers 1 & 2 	Blowmold grinders 	Cheese palletizer 	Raw tank agitator
Recent events (3)
  • — F (S) $13653
  • — C (S) $13653
  • — Z (S) $13653

1910.147 C04 I

Willful Gravity 10 2 instances 4 exposed
Issued
Aug 10, 2021
Abate by
Jun 28, 2022
Penalty
Initial $136,532 · Current $136,532
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 12, 2021, machine specific, step-by-step procedures were not developed, documented and utilized for the control of potentially hazardous energy when maintenance employees worked on the Uniloy Milacron Model 350 R5 Blowmold Machine #1, serial number 350R5-3149.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards.  b) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 12, 2021, machine specific, step-by-step procedures were not developed, documented and utilized for the control of potentially hazardous energy when maintenance employees worked on the Uniloy Milacron Model 350 R5 Blowmold Machine #2, serial number 350R5-3156.  This condition exposed maintenance employees to burn, caught-in-between, crushing, and amputation hazards.
Recent events (3)
  • — F (W) $136532
  • — C (W) $136532
  • — Z (W) $136532

1910.212 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Aug 10, 2021
Abate by
Jun 28, 2022
Penalty
Initial $136,532 · Current $86,520 Reduced
29 CFR 1910.212(a)(3)(ii):  The point of operation of machines whose operation exposes an employee to injury, shall be guarded:  a) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 12, 2021, the employer did not ensure employees were protected from injury, in that operators frequently made parison adjustments on the Uniloy Milacron Model 350R5 Blowmold Machine #1, serial number 350R5-3149, without the two platen covers installed.  These adjustments were also made with both unsecured platens being slid back to their stops which exposed employees to the point of operation.  This condition exposed employees to caught-in-between, crushing, and amputation hazards.  b) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 12, 2021, the employer did not ensure employees were protected from injury, in that operators frequently made parison adjustments on the Uniloy Milacron Model 350R5 Blowmold Machine #2, serial number 350R5-3156, without the two platen covers installed.  These adjustments were also made with both unsecured platens being slid back to their stops which exposed employees to the point of operation.  This condition exposed employees to caught-in-between, crushing, and amputation hazards.
Recent events (3)
  • — F (S) $86520
  • — C (W) $136532
  • — Z (W) $136532

1910.101 B

Other-than-serious 1 instance 5 exposed
Issued
Aug 10, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:   a) Safeway Inc., at 4301 Forest Street, Denver CO 80216: On or before February 16, 2021, the employer did not ensure that compressed gas cylinders were secured in accordance with Section 3.3.1 of the Compressed Gas Association Pamphlet P-1-1965, in that a nitrogen cylinder located in the middle of the room behind the Blowmold Machines was upright and not secured.  This condition potentially exposed employees to fire and struck-by hazards.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Safeway, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345148852.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.