BOISE, ID —
OSHA Inspection: VISSER BUILDING CO, L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VISSER BUILDING CO, L.C. in 505 WEST BANNOCK STREET, BOISE, ID 83702 (NAICS 236115). OSHA activity number 345162721.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VISSER BUILDING CO, L.C.
- Site address
- 505 WEST BANNOCK STREET
- City
- BOISE
- State
- ID
- ZIP
- 83702
- Mailing
- 8312 W NORTHVIEW ST STE 120, BOISE, ID 83704
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 1
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B01
- Issued
- May 3, 2021
- Abate by
- May 20, 2021
- Penalty
- Initial $3,686 · Current $1,843 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not have an effective system in place to correct hazards to which their subcontractors were exposed. These hazards include but may not be limited to fall hazards up to 16 feet, on and around the interior spiral stairway. b) On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not have an effective system in place to correct hazards to which their subcontractors were exposed. These hazards include but may not be limited to maintaining proper machine guarding on table saws used to cut finish woodwork. Note) Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $1843
- — Z (S) $3686
1926.501 B01
- Issued
- May 3, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not ensure sub-contractors protected their employees from fall hazards. Sub-contractor employees performed work, including but not limited to finish carpentry work, on or near the interior spiral stairway landing without a fall protection system in place. This exposed the employee(s) to a 16 foot fall hazard the floor below. Note) Corrected during inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1052 C04
- Issued
- May 3, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(4): Mid rails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stair rail system and the stairway steps: a) Interior spiral stairway: On February 24, 2021; the controlling employer, Visser Building Co., L.C. did not ensure sub-contractors protected their employees from fall hazards while working on the interior spiral stairway. Top rails and mid rails were missing at various locations along the stair rail system. Note) Corrected during inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.304 H01
- Issued
- May 3, 2021
- Penalty
- Initial $2,633 · Current $1,317 Reduced
General-duty citation text
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood that meets all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws: a)Jobsite: On February 24, 2021; the controlling employer, Visser Building Company, did not ensure a sub-contractor protected their employees from amputation hazards while performing finish carpentry work. An employee used a 10 inch Metabo table saw with the upper blade guard removed. Note) Corrected during inspection
Recent events (2)
- — I (S) $1317
- — Z (S) $2633
1926.304 I01
- Issued
- May 3, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1):Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed the portion of the saw above the table and that portion of the saw above the material being cut: a) Jobsite: On February 24, 2021; the controlling employer, Visser Building Co., L.C., did not ensure a sub-contractor protected their employees from amputation hazards while performing finish carpentry work. An employee used a 10 inch Metabo table saw with the upper blade guard removed. Note) Fixed during inspection.