AKRON, OH —
OSHA Inspection: FOUNDATION INDUSTRIES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FOUNDATION INDUSTRIES INC. in 880-B WATERLOO ROAD, AKRON, OH 44314 (NAICS 326199). OSHA activity number 345165286.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FOUNDATION INDUSTRIES INC.
- Site address
- 880-B WATERLOO ROAD
- City
- AKRON
- State
- OH
- ZIP
- 44314
- Mailing
- 880-B WATERLOO ROAD, AKRON, OH 44314
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 43
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 21, 2021
- Abate by
- Jun 30, 2021
- Penalty
- Initial $6,827 · Current $4,714 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 25, 2021 the employer failed to ensure that specific procedures for the control of hazardous energy during servicing and maintaining of equipment in the facility were in place. Employees are tasked with servicing and maintaining of equipment including but not limited to saws, wood milling machines, routers, and other wood working machines. Hazardous energies present on the equipment includes pneumatic, mechanical, and electrical. Procedures were not in place with sufficient detail and adequate guidance for an authorized employee(s) to clearly understand how to safely and effectively utilize hazardous energy control measures for the particular machine or piece of equipment being serviced and/or maintained.
Recent events (2)
- — I (S) $4714
- — Z (S) $6827
1910.147 C06 I
- Issued
- Apr 21, 2021
- Abate by
- Jun 30, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about February 25, 2021 the employer failed to ensure that a periodic inspection of the machine specific procedures for equipment serviced and maintained in the facility had taken place. Employees are tasked with servicing and maintaining of equipment including but not limited to saws, wood milling machines, routers, and other wood working machines. Hazardous energies present on the equipment includes pneumatic, mechanical, and electrical.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Apr 21, 2021
- Penalty
- Initial $5,803 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about February 25, 2021 the employer failed to ensure that effective machine guarding was in place on the automatic wood routing machine (Maypro Cablematic #C832). Barrier guarding was not in place on the non-operator side allowing employees to enter the cell area where the movement of the machine and point of operation of the router was not enclosed.
Recent events (2)
- — I (O) $0
- — Z (S) $5803
1910.333 A01
- Issued
- Apr 21, 2021
- Penalty
- Initial $5,803 · Current $2,902 Reduced
General-duty citation text
29 CFR 1910.333(a)(1): Live parts that the employee was exposed to were not de-energized before the work began in or near them. On or about February 25, 2021 the employer failed to ensure that the electrical components of the hydraulic press (Hidrogarne model CD45/65F) in the Nail room were deenergized prior to employees working near the exposed electrical conductors. The control panel labelled as containing 480v equipment was opened and the main control switch operated inside the panel by employees.
Recent events (2)
- — I (S) $2902
- — Z (S) $5803
More inspections at Foundation Industries INC.
View Foundation Industries INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345165286.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.