PLAIN CITY, OH —
OSHA Inspection: EDUARDO LOPEZ
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EDUARDO LOPEZ in 10577 ASH GROVE COURT, PLAIN CITY, OH 43064 (NAICS 238130). OSHA activity number 345180467.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDUARDO LOPEZ
- Site address
- 10577 ASH GROVE COURT
- City
- PLAIN CITY
- State
- OH
- ZIP
- 43064
- Mailing
- 4670 HILTON AVENUE APT. 21, COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B01
- Issued
- Jul 19, 2021
- Abate by
- Aug 6, 2021
- Penalty
- Initial $2,926 · Current $2,926
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. a. On or about March 3, 2021, and at times prior, the employer did not initiate and maintain safety and health programs to ensure their employees were protected from the hazards associated with residential framing construction. Employees were working from heights without fall protection and utilizing power tools without proper eye protection. As a result, employees were exposed to hazards such as, but not limited to, falls from heights and struck-by hazards associated with the residential framing activities.
Recent events (1)
- — Z (S) $2926
1926.102 A01
- Issued
- Jul 19, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a. On or about March 3, 2021, and at times prior, an employee was operating a portable circular saw and pneumatic nail gun without the use of eye protection. The employee was thereby exposed to struck-by hazards associated with flying particles.
Recent events (1)
- — Z (S) $4096
1926.501 B13
- Issued
- Jul 19, 2021
- Abate by
- Aug 2, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. a. On or about March 3, 2021, and at times prior, employees were engaged in framing activities above 6 feet without the use of fall protection measures. An employee was installing sheathing on the roof of a residential structure without the use of fall protection measures and was thereby exposed to falls from heights of approximately 18 feet.
Recent events (1)
- — Z (S) $4096
1926.403 B01 I
- Issued
- Jul 19, 2021
- Abate by
- Jul 29, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1)(i): Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose. a. On or about March 3, 2021, and at times prior, a relocatable power tap was utilized with extension cords plugged into it with accompanying power tools. This relocatable power tap was not utilized in accordance with its listing and labeling purpose. Employees were thereby exposed to electrical fire hazards.
Recent events (1)
- — Z (O) $0
More inspections at Eduardo Lopez
View Eduardo Lopez's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345180467.