Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ICD PLUS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ICD PLUS, LLC in 613 4TH ST, WESTWEGO, LA 70094 (NAICS 238190). OSHA activity number 345184899.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ICD Plus, LLC — free Get an email when a new federal OSHA severe-injury report for ICD Plus, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ICD PLUS, LLC
Site address
613 4TH ST
City
WESTWEGO
State
LA
ZIP
70094
Mailing
19123 GREENLEAF CIRCLE, PONCHATOULA, LA 70454
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.95 A

Serious Gravity 10 1 instance 6 exposed
Issued
May 10, 2021
Abate by
May 28, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided:  a) On or about March 9, 2021, between the two buildings, employees working in close proximity to power lines with an unknown voltage were not provided with electrical protective equipment including, but not limited to rubber insulating blankets, rubber insulating matting, rubber insulating covers, rubber insulating line hose, rubber insulating gloves, and rubber insulating sleeves.
Recent events (1)
  • — Z (S) $4096

1926.416 A01

Serious Gravity 10 1 instance 6 exposed
Issued
May 10, 2021
Abate by
May 28, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a) On or about March 9, 2021, between the two buildings, employees worked in close proximity to a power line with an unknown voltage without first guarding the circuits by insulation or contacting power source for de-energizing.
Recent events (1)
  • — Z (S) $4096

1926.416 A03

Serious Gravity 10 1 instance 6 exposed
Issued
May 10, 2021
Abate by
May 28, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit:  a) On or about March 9, 2021, between the two buildings, signs were not posted identifying overhead power lines that were in close proximity to the building. In addition, the employer did not warn employees about the hazards or the proper protective measures to be taken when they worked in close proximity to the overhead power lines.
Recent events (1)
  • — Z (S) $4096

1926.451 F06

Serious Gravity 10 1 instance 6 exposed
Issued
May 10, 2021
Abate by
May 28, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):  a) On or about March 9, 2021, between the two buildings, employees worked from scaffolding that was erected less than 3 feet from an insulated power line with an unknown voltage without first contacting the utility company or installing protective coverings to prevent accidental contact with the lines.
Recent events (1)
  • — Z (S) $4096