PLEASANTON, TX —
OSHA Inspection: NEXTIER COMPLETION SOLUTIONS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NEXTIER COMPLETION SOLUTIONS in 586 CO RD 429, PLEASANTON, TX 78064 (NAICS 213112). OSHA activity number 345185193.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEXTIER COMPLETION SOLUTIONS
- Site address
- 586 CO RD 429
- City
- PLEASANTON
- State
- TX
- ZIP
- 78064
- Mailing
- 3990 ROGERDALE, HOUSTON, TX 77042
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 47
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Sep 3, 2021
- Abate by
- Sep 24, 2021
- Penalty
- Initial $13,653 · Current $8,192 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about March 08, 2021, and at times prior thereto, employees were exposed to a struck-by hazard from pressurized hydraulic fluid while starting pumps on a pump truck without developing and documenting procedures for the control of hydraulic and electrical energy.
Recent events (2)
- — I (S) $8191.8
- — Z (S) $13653
1910.147 C04 II B
- Issued
- Sep 3, 2021
- Abate by
- Sep 24, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about March 08, 2021, and at times prior thereto, employees were exposed to a struck-by hazard from pressurized hydraulic fluid spraying from a pump truck when performing diagnostics without energy control procedures in place.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345185193.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.