OSHA Inspection: URBAN OUTFITTERS, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of URBAN OUTFITTERS, INC in 5000 S. BROAD ST. BUILDING 543, PHILADELPHIA, PA 19112 (NAICS 448140). OSHA activity number 345186282.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Urban Outfitters, INC — free Get an email when a new federal OSHA severe-injury report for Urban Outfitters, INC is published. One employer, no account, unsubscribe in one click.
Site address
5000 S. BROAD ST. BUILDING 543
City
PHILADELPHIA
State
PA
ZIP
19112
Mailing
5000 S BROAD ST., PHILADELPHIA, PA 19112
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
448140
Employees
2092
Ownership type
A

5 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 3, 2021
Abate by
Sep 20, 2021
Penalty
Initial $13,653 · Current $8,874 Reduced
29 CFR  1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  a) Jobsite located at 5000 S. Broad St. Philadelphia, PA - 19112: The employer did not provide company specific training regarding safety-related work practices to employees conducting troubleshooting operations inside an energized (480V) HVAC control panel, thus exposing employees to electrical hazards. An employee suffered severe injuries after coming in contact with an energized (480V) exposed conductor while attempting to obtain voltage readings.   Noted on or about March 4, 2021.
Recent events (2)
  • — I (S) $8874.45
  • — Z (S) $13653

1910.335 A01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 3, 2021
Abate by
Sep 20, 2021
Penalty
Initial $13,653 · Current $8,874 Reduced
29 CFR  1910.335(a)(1)(i):Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:  Jobsite located at 5000 S. Broad St. Philadelphia, PA - 19112: The employer did not ensure that electrical protective equipment was being used by employees who conduct troubleshooting operations inside energized (480V) HVAC control panels thus exposing employees to electrical hazards. An employee suffered severe injuries after coming in contact with an energized (480V) exposed conductor while attempting to obtain voltage readings.   Noted on or about March 4, 2021.
Recent events (2)
  • — I (S) $8874.45
  • — Z (S) $13653

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Sep 3, 2021
Abate by
Sep 7, 2021
Penalty
Initial $9,753 · Current $6,339 Reduced
29 CFR  1904.39(a)(2):The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye:  a) Jobsite located at 5000 S. Broad St. Philadelphia, PA - 19112: On March 4, 2021, an employee was admitted to the hospital as an in-patient for treatment of work-related incident upon exposure to an energized (480V) electrical control panel of an HVAC fan coil unit and falling approximately 5ft. from a ladder to the floor of the work site (kitchen of bldg. #543) and sustaining injuries that resulted in a 5-day hospital admission. The employer reported on the in-patient hospitalization on March 8, 2021.    Noted on or about March 4, 2021.
Recent events (2)
  • — I (O) $6339.45
  • — Z (O) $9753

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 3, 2021
Abate by
Sep 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i):The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a) Jobsite located at 5000 S. Broad St. Philadelphia, PA - 19112: The employer did not conduct an annual review of the company's energy control procedures, ensuring procedures are established and followed pertaining to hazardous energy and the unplanned discharge of it within the Urban Outfitters campus.  Condition was noted on or about April 16, 2021.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 D02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Sep 3, 2021
Abate by
Sep 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2):The employer did not verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated; the person which certified that the evaluation had been performed; the date(s) of the hazard assessment; and, which identified the document as a certification of hazard assessment:  a) Jobsite located at 5000 S. Broad St. Philadelphia, PA - 19112: The employer did not conduct a workplace hazard assessment, properly identifying the hazard(s) associated with specific processes and adequate personal protective equipment (PPE) for employee use; thereby, exposing employees to hazards such as electrical, etc. An employee suffered severe injuries after coming in contact with an energized (480V) exposed conductor while attempting to obtain voltage readings.   Noted on or about March 4, 2021.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Urban Outfitters, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345186282.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.