Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FIBEROPTICS TECHNOLOGY INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FIBEROPTICS TECHNOLOGY INC. in 1 QUASSETT ROAD, POMFRET, CT 06258 (NAICS 333314). OSHA activity number 345186944.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fiberoptics Technology INC. — free Get an email when a new federal OSHA severe-injury report for Fiberoptics Technology INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 QUASSETT ROAD
City
POMFRET
State
CT
ZIP
06258
Mailing
P.O. BOX 286, POMFRET, CT 06258
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333314
Employees
177
Ownership type
A

4 citations on file for this inspection.

1910.106 E02 IV D

Serious Gravity 5 1 instance 10 exposed
Issued
May 7, 2021
Abate by
Jun 24, 2021
Penalty
Initial $5,969 · Current $4,178 Reduced

Hazardous substances 1560

29 CFR  1910.106(e)(2)(iv)(d):Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:  OLD BARN ASSEMBLY AREA:  On or about March 16, 2021, the self-closing valve on a safety can used for the storage of isopropyl alcohol did not close after liquid was no longer being dispensed.
Recent events (2)
  • — I (S) $4178.3
  • — Z (S) $5969

1910.303 B02

Serious Gravity 5 1 instance 10 exposed
Issued
May 7, 2021
Penalty
Initial $8,953 · Current $6,267 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  OLD BARN BREAK ROOM:  On or about March 16, 2021, a GE 15-amp relocatable power tap  was subject to being overloaded as it provided power to a Hamilton Beach 11.25-amp microwave oven and a 6.67-amp Oster toaster.  The outlet ampacity rating was exceeded.  Employees were exposed to burns and electric shocks from overloaded equipment.
Recent events (2)
  • — I (S) $6267.1
  • — Z (S) $8953

1910.303 B07 IV

Serious Gravity 5 1 instance 12 exposed
Issued
May 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(7)(iv):  Electric equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  BREAK ROOM, OLD BARN:  On or about March 16, 2021, the outer casing on a GE relocatable power tap that was used to energize a Hamilton Beach microwave oven and an Oster 2-slice toaster was melted, showing evidence of overheating.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 B04 II B

Serious Gravity 5 1 instance 12 exposed
Issued
May 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.304(b)(4)(ii)(B):  Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  EMPLOYEE BREAK ROOM, OLD BARN:  On or about March 16, 2021, a GE relocatable power tap was used to energize a Hamilton Beach microwave oven and an Oster 2-slice toaster.  The microwave was rated at 1350 watts (11.25 amps) and the toaster was rated at 800 watts (6.67 amps).   The power tap was rated for 15 amps.  According to Table S-4, the maximum allowed load is 12 amps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Fiberoptics Technology INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345186944.