VALDOSTA, GA —
OSHA Inspection: JACUZZI INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JACUZZI INC in 512 HIGHLAND DR., VALDOSTA, GA 31601 (NAICS 326191). OSHA activity number 345187355.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JACUZZI INC
- Site address
- 512 HIGHLAND DR.
- City
- VALDOSTA
- State
- GA
- ZIP
- 31601
- Mailing
- 512 HIGHLAND DR., VALDOSTA, GA 31601
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326191
- Employees
- 200
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 11, 2021
- Abate by
- Jun 28, 2021
- Penalty
- Initial $12,288 · Current $7,373 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the site in the trim and drill area, on or about March 10, 2021, the employer did not develop lockout tagout procedures for a cable system used to open and close the robot door, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $7372.8
- — Z (S) $12288
1910.147 C04 II B
- Issued
- May 11, 2021
- Abate by
- Jun 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) At the site in the trim and drill area, on or about March 10, 2021, the employer did not develop lockout tagout procedures for a cable system used to open and close the robot door, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II C
- Issued
- May 11, 2021
- Abate by
- Jun 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. a) At the site in the trim and drill area, on or about March 10, 2021, the employer did not develop lockout tagout procedures for a cable system used to open and close the robot door, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- May 11, 2021
- Abate by
- Jun 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control a) At the site in the trim and drill area, on or about March 10, 2021, the employer did not develop lockout tagout procedures for a cable system used to open and close the robot door, exposing employees to amputation hazards.
Recent events (2)