OSHA Inspection: RHOADES & COMPANY SIDING INSTALLATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RHOADES & COMPANY SIDING INSTALLATION in 180 MAIN STREET, GLASTONBURY, CT 06033 (NAICS 238170). OSHA activity number 345191928.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rhoades & Company Siding Installation — free Get an email when a new federal OSHA severe-injury report for Rhoades & Company Siding Installation is published. One employer, no account, unsubscribe in one click.
Site address
180 MAIN STREET
City
GLASTONBURY
State
CT
ZIP
06033
Mailing
793 BURNHAM STREET, EAST HARTFORD, CT 06108
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 B05 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2021
Penalty
Initial $2,926 · Current $0 Reduced
29 CFR  1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end.   On or about March 11, 2021, at the 180 Main Street, South Glastonbury, CT job site:  The pump jack scaffold system in use had a 22 ft long  platform that extended over its end support by more than 10 ft.   The scaffold was not designed or installed so that the cantilevered portion of the platform was able to support employees without tipping and the scaffold did not have a guardrails which block employee access to the cantilevered end.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2926

1926.451 C02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    On or about March 11, 2021, at the 180 Main Street, South Glastonbury, CT job site:  The  poles for the pump jack scaffold system  in use were not placed on base plates, mud sills or other adequate firm foundation to ensure the stability of the scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2021
Penalty
Initial $2,926 · Current $0 Reduced
29 CFR  1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.     On or about March 11, 2021 at 180 Main Street, South Glastonbury, CT job site:  The pump jack system that was in use, was not installed with standard guardrails around open sides of the scaffold, exposing those using the scaffold to fall hazards in excess of 12 ft.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2926

1926.452 J03

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.452(j)(3): When guardrails are used for fall protection, a workbench may be used as the toprail only if it meets all the requirements in paragraphs (g)(4)(ii), (vii), (viii), and (xiii) of 1926.451.    On or about March 11, 2021, at the 180 Main Street, South Glastonbury, CT job site:  The work bench that was being used as a top rail on the pump jack scaffold system did not meet the requirements to be used as substitute for a top guardrail. The bench was not located between 38" and 45" above the working surface on both ends and the work bench was not secured to the structure to ensure that it could withstand a force of 200 lbs in any direction without failure in the event that someone fell against it.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0